Fortress Evault Canada – Fortress battery methods make the most of the industry’s most environmentally benign chemistry- Lithium Ferro Phosphate, which eliminates working temperature constraints, toxic coolants, and the risk of thermal runaway and hearth. The built-in smart Battery Management System (BMS) integrates multilevel safety concepts: Overcharge and Deep Discharge Protection; Voltage and Temperature Observation; Cell balancing.
Fortress Evault Canada
Fortress high-performance Lithium Batteries are manufactured on the highest high quality normal. It comes with a large power capability and fast charging and continuous discharge power. The proprietary architecture and BMS eliminate the need for cooling or air flow, which creates an efficient round-trip conversion.
The Fortress Lithium Battery is protected, easy to put in, constantly dependable, and extremely environment friendly. It provides you the lowest lifetime energy cost
Reviews Fortress Power 18.5kWh
They have their own touchscreen display that gives you with the state of charge the battery voltage, your current flow in and out of the battery bank. Each battery has a 250 amp breaker on the top. So, from the terminals on the battery, its overcurrent protection 250 amps out to the masses. You might straight hook these as much as an inverter, or you would wire them to a excessive current bus, and parallel multiple batteries together to gain a suitable capacity to your utility.
This battery is nice for larger-scale off-grid applications usually, the minimal obviously is going to be 18 kilowatt-hours. But, if you want to have constructing blocks of 18-kilowatt-hour chunks, that’s the place this specific battery is going to be finest suited.
Fortress eVault 18.5kWh
So, you realize typically we’ll be using these batteries for applications which might be 30 kilowatt hours or more, because of the numerous building blocks on account of the 18 kilowatt-hour capability of every of these particular person banks.
Another cool function of this battery is, that it’s on casters. So, it weighs about 400 pounds but transferring it round to where its final resting place is going to be is fairly easy with the casters. This explicit battery has knockouts on the sides. On both facet, it permits you to put in like a one-inch conduit, or one-inch string aid right into the battery.
eVault 18.5kWh Specifications
eVault 18.5 | |
Total Energy (kWh) | 18.5 |
Capacity | 360 Ah |
Nominal Voltage | 51.2 (48) V |
Voltage Range | 45-58.4 Ah |
Recommended Charge Current | 100 A |
Max. Charge Current (Continuous) | 170 A |
Max. Discharge Current (Continuous) | 180 A |
Max. Pulse Current (for 10 sec) | 200 A |
Charging Temperature | 32 to 113 F |
Discharging Temperature | 32 to 113 F |
Recommended Storage Temperature | 50 to 95 F |
Dimension (H xW x D, inch_ | 38.8 x 19.2 x 21.3 |
Weight | 476 lbs |
Enclosure Protection Rating | IP21 |
Mounting options | Floor standing |
Certificates | UL 1624 |
Warranty | 5/10 Years |
Scalability | Maximum 12 in Parallel (222 kWh) |
Communication | CAN/RS485 |
High Current Circuit Breaker | 250A |
Efficiency | 98% |
Fortress Power VS Tesla Powerwall
Comparison between the Fortress power battery and the Tesla Powerwall battery. The very first thing that I will mention is the protection of our battery system. Fortress uses lithium iron phosphate chemistry in addition to being extra safer than the Tesla Powerwall chemistry.
Specifications | Fortress Power | Tesla Powerwall |
---|---|---|
Battery Chemistry | LFP | NMC |
Safety | Yes | No |
Usable Power | 16,5 | 13.5 kWh |
No. of Parallel Stacking | 8 | 10 |
Guaranteed Battery Cycles | 6.000 | 2.800 |
LCD Display | Yes | x |
Continuous Power | 8.2 KW | 5 KW |
Peak Output | 12 kW | 7 KW |
This security additionally allows us to have more power and longer period that means, that we have now a 40% more storage capacity and a 100%, 40 percent extra output, meaning that you simply’re capable of power extra appliances to your longer amount of time.
Fortress Evault Canada – Fortress gives a 10-year guarantee with around a 12 to 15-year lifespan whereas Tesla offers around half of that maybe six to seven, eight years of lifespan. Now, you are probably wondering how did you calculate this in terms of safety and longevity.
Fortress Power 5.4kW
We calculate this utilizing energy throughput. Energy throughput is the entire quantity of energy a battery might be anticipated to retailer and deliver over its lifetime. So, for those who see here the afford clear evil has 88.8 make watt-hours of energy throughput.
The checks of Powerwall has solely 37.8 make loads of hours of energy throughput, most exhibiting that our battery just isn’t solely safer but gonna last a heck of so much longer. And lastly, I’d prefer to convey up the cost. So, you may see here, the fortress power system right here on the left, and the 2 Tesla Powerwall here on the correct.
The put in cost of the fortress system is lower than that of the Tesla Powerwall with a bigger inverter but additionally has a for much longer energy throughput of 88.8 compared to 75.6. So, you may see after we take this, and we get the cost per greenback per kilowatt-hour the fortress power system is actually extra environment friendly and better when it comes to the dollars per kilowatt-hour that is being paid.
Fortress Power VS Sonnen Eco
Fortress Power VS Solar Edge
Fortress Power VS Pika Energy
Fortress Evault Installation
1. Mounting and securing the battery
The Fortress eVault 18.5 is designed to stand on the floor with 4 wheels on the bottom. If desired, the wheels can be disassembled. We recommend putting the batteries on durable racks to avoid flooding. Please refer to the Fortress Lithium Battery Data Sheet for weight and dimension.
2. Mounting the battery pack to a wall
- Fasten the screws through the mounting brackets into the holes of the battery pack on both sides.
- Secure the mounting brackets to the wall with screws. Make sure to leave a space of
at last 2.18 inches in between the battery pack and the wall. - Lock the rollers on the battery pack
3. Connecting the battery to the Charge Controller and/or Hybrid Inverter
The battery terminals are positioned under the top cover. Please use the screwdriver to take
the screws along the top cover off.
Please make sure the breaker near the terminal is in the OFF position. Please install the positive cable first and the negative cable second. Please do not cross the positive and negative terminals; also, ensure the terminals are not connected to any metal mounting, fixture, or body part. Recommended terminal torque is 7.0 – 7.7 Nm (5.1 – 5.7 ft-lb)
The Fortress Lithium Batteries are equipped with two M8 threaded terminals with a lock washer and nut. The right-hand stud resides in a red high-temperature molded insert. This connection is for the positive lead. The left-hand stud resides in a black high-temperature insert. This connection is for the negative lead. 8mm ring terminals along with proper size wiring cables are required to connect the battery to the inverter/charger. Do not reverse polarity, doing so will void the warranty. Use a voltmeter to check polarity before connecting terminals.
Download For eVault 18.5 kWh Details Installation
Download For eFlex 5.4 kWh Details Installation
Download For LFP-10 Details Installation
Download For LFP-5k-48V Details Installation
Other Articles Review
- Titan For Simple Off Grid Living
- JACKERY EXPLORER 1500 Solar Generator Review
- Bigbattery Powerblock LiFePO4 Reviews
- EcoFlow RIVER Pro Review and Testing
- Reviews Fortress Power eVault 18.5kWh Lithium Battery