Kilovault V2 Vs V3 – KiloVault® is dedicated to providing revolutionary and affordable renewable energy solutions for residential and business applications.
KiloVault® design, market, and sell energy storage and power conversion merchandise based mostly on leading-edge technologies, that scale back the cost of entry for homeowners, and assist cut back the impact of humanity on the setting.
Kilovault V2 Vs V3
KiloVault® has greater than 20 years of expertise designing renewable energy systems. Our founders and lead development engineers have unique insight into the needs of the residential power. This is simply their newest thought to help prospects store the sun, and save the planet.
Product Overview
Kilovault V2 Vs V3 – KiloVault® Solar Energy Storage merchandise cowl a wide range of functions, including Flexible Energy Storage, Wall-Mount Energy Storage, and Portable Emergency Power.
1. KiloVault HLX Series
KiloVault HLX-Series Deep- Cycle Lithium Batteries provide a configurable approach to residential energy storage needs. The HLX Series can be used individually or in combination for 12, 24, or 48-volt techniques, with storage capacities ranging from 150 Amp-hours to 1,200 Amp-hours.
KiloVault HLX Series Features:
- Flexible – Works in 12, 24, or 48V configurations
- Gives You More- You can use the full battery’s capability, discharging it 100%
- Long-life- Even after discharging it fully 2000 times, 80% of the capability remains.
- Maintenance Free – No watering required, or cleaning of hazardous chemicals
- High Efficiency – Giving you as much as 12% more use-able stored vitality
- Smart Investment – Lower value per watt-hour/cycle and a longer lifespan than lead batteries
- Safer – No thermal run-away issues as with different lithium applied sciences
- Heavy Duty -Takes as much as 150A of continuous charging/discharging current, assembly the tough calls for of serious inverters and chargers
- 7.5 Year Warranty
KiloVault HLX Series Product Specifications:
1200 HLX | 1800 HLX | 3600 HLX | |
---|---|---|---|
Battery Type | Li-FePO4 | Li-FePO4 | Li-FePO4 |
Rated Capacity | 1200Wh | 1800Wh | 3600Wh |
Rated Voltage | 12.8 V DC | 12.8 V DC | 12.8 V DC |
Nominal Amp-Hour Capacity | 100Ah | 150Ah | 300Ah |
Continuous Discharge Current | 100A | 150Ah | 150Ah |
Maximum Discharge Current | 100A | 150Ah | 200A for 30 min, 150A (continuous) |
Max Charge Current | 80A | 150Ah | 150Ah |
Peak Discharge Current < 3 secs | 350A | 500A | 500A |
Dimensions | |||
Length | 12.5 in (318 mm) | 19.1 in (485 mm) | 20.5 in (520 mm) |
Width | 6.5 in (165 mm) | 6.7 in (170 mm) | 8.7 in (220 mm) |
Height | 8.5 in (215 mm) | 9.4 in (240 mm) | 10.6 in (269 mm) |
Battery Weight | 27 lbs (12.2 kg) | 41.7 lbs (18.9kg) | 84.4 lbs (38.3 kg) |
Shipping Weight | 30 lbs (13.6 kg) | 45.2 lbs (20.5kg) | 103.4 lbs (46.9 kg) |
KiloVault 1800 HLX
2. KiloVault RES-Q
KiloVault RES-Q Portable Emergency Power Unit features a 1,200 Watt-Hour battery, charge controller, and inverter that can energy a refrigerator and charge cell telephones. The KiloVault RES-Q is designed to be charged by solar panels, a backup generator, or commonplace 120 VAC power, and can provide as much as 1200Wh of emergency backup power.
KiloVault RES-Q Features:
- 1500W Pure Sinewave Inverter
- 1200Wh KiloVault Lithium Battery
- 25A Solar Charge Controller
- Built-in AC Charger
- Liquid Crystal Display Status
- 2x 120V Outlets
- 1x 12V Cigarette Lighter Adapter
- Lead Acid Battery Expansion Port
KiloVault RES-Q Specifications:
1500 RES-Q | |
---|---|
Rated Energy Capacity (Watt Hours) | 1280 Wh |
DC Voltage Nominal | 12.8V |
Nominal Amp-Hour Capacity | 100 Ah |
Cycle Rating | 2500+ cycles @ 80% Depth of Discharge |
Minimum Charge Time | 2.5 Hours |
Charge Retention | 1 Year (85%) |
Integrated Inverter | 1500W continuous output/120VAC pure sinewave/Slow begin characteristic protects inverter from over-current draw |
Maximum Charge Current | 15A @ 12V from AC or DC circuitry |
Maximum DC Output | 20A |
Operating Temperature | 23 – 111°F (-5 – 45°C) |
Surge Ratings | 3000W (5ms), Soft Start (for short surges) |
Environmental Rating | Indoor rated only – not rated for rainy, damp, snowy conditions |
Expansion Port for External Battery | We extremely advocate utilizing an LFP battery (ie. KiloVault). The RES-Q completely discharges the external battery, all the way down to 10.5V, before switching to the inner battery. Completely discharging a lead-acid battery will doubtless damage it and completely scale back its capacity. |
Warranty | 2 Year Limited |
Dimensions | |
Length | 18.9 in (480 mm) |
Width | 9.4 in (238 mm) |
Height | 15.7 in (400 mm) |
Weight | 61.7 lbs (28 kg) |
KiloVault RESQ 1500
KiloVault HLX Tips And FAQ
Is it good to insulate the KiloVault battery?
It’s the identical with any type of battery. Because batteries heat up once they charge, when you insulate the field they’re in, it can retain the heat better and the batteries will keep warmer. But be certain that to remove the insulation in the hot months, as overheated batteries could have a shorter life.
What is the best operating and storage temperature for the KiloVault?
The optimal temperature range overall is 59 – 95°F (15 – 35°C). Full operating temperatures should be higher than 32°F (O°C) and less than 133°F (45°C). Charging the battery below 32°F (0°C) will doubtlessly damage it.
What are the really useful charge controller/inverter settings?
We extremely recommend setting the Bulk/Absorb voltage to *14.0V* for a 12V system (*28.0V* for 24V system, *56.0V* for 48V), float voltage of 13.8V (27.6V for 24V, 55.2V for 48V). Higher settings will cut back the *life* of the batteries. For the inverter low voltage cut-off we strongly advocate 12.0V *or increased* (24.0V, for 24V methods, 48.0V for 48V techniques). Limit the period of the take in voltage interval to 2 minutes if the charger is greater than 100A, in any other case set to five minutes.
Are there any concerns when wiring the batteries in parallel?
Yes – for the HLX sequence batteries, the maximum configuration is 4 parallel strings of 4 sequence batteries (16). In addition, when adding another parallel row of batteries to an existing one, you will need to keep all parallel collection strings within 0.2V of each other. Before including a new row of batteries to an current one, charge all batteries to 100% first.
For the CHLX sequence batteries, a most of 4 batteries can be utilized in sequence or parallel, but NOT each. The CHLX are programmed so that when they are in parallel or series if one will get chilly enough to start heating, all the CHLX in sequence or parallel will start heating. This is to prevent widely different energy attracts and states of charge within the battery bank when some are heating and can’t charge, whereas others are warm sufficient to charge. As the communication between the CHLX occurs through the power cables, if connected this way, this communication can’t take place.
Can I mix and match models or manufacturers?
No – this isn’t good observe with any battery financial institution.
Should I do an equalization charge on the batteries?
No- very like AGM batteries, an equalization charge might damage them by overcharging them.
Are the batteries shipped absolutely charged, or do I must charge them?
No – transport tips do not enable deep cycle batteries to be totally charged during cargo. **Before you place the batteries into operation they need to ALL be charged to exactly the identical voltage (select a voltage between 14.0-14.4, V however be sure they are *ALL* the identical). This will make sure you begin with an even charge across the battery bank. Suggested battery charger (cables not included with this charger but can be found – use merchandise code ALTCC-6AWG-60RB). We do NOT suggest using the Iota IQ-LIFE PO Smart Charger accessory to be used with KiloVault batteries because the charge voltage is just too high.
Can I do a constant trickle charge on the batteries?
Storing the batteries with a constant small trickle charge just isn’t beneficial. Unlike lead-acid batteries, lithium iron phosphate batteries self-consume vitality at such a low rate (0.020 amps or about 6 Watt-hours/day), the battery can be simply over-charged if put on a trickle charger. Over-charging the battery triggers the over-charge safety – shutting it down until the voltage goes down sufficient by itself. Once that occurs the trickle charger would quickly raise the voltage up too excessive once again. As a consequence, the fixed biking of this circuitry will shorten the life of your complete battery.
Is it unhealthy to overcharge or over-discharge the battery?
Yes, it will lower the life of the battery. It’s really helpful to by no means discharge or charge the battery to the purpose the place it has to close down to guard itself.
View Complete KiloVault Product And Discount Price
Customer Reviews
Kilovault V2 Vs V3 – I’ve been working my new system with the KiloVault 3600 HLX for 2 weeks and it really works improbable. I’ve watched it put out 168 amps with no problem and solely a pair tenths drop in voltage while doing it after which instantly returns to the traditional 13. 3 volts.
I’ve seen it charge in a short time at 68 amps from my photovoltaic array. The solely problem I have had is that the BMS will put this battery on standby when my PV input matches the load on the battery… your entire system “pauses” inflicting the inverter to close off, the charge controller goes to relaxation, or to alarm and the 12-volt system goes lifeless for a couple of seconds… Be suggested the battery can go on standby…
View More KiloVault Helpful Reviews