Product Overview
Kilovault Review – KiloVault® Solar Energy Storage merchandise cowl a wide range of purposes, including Flexible Energy Storage, Wall-Mount Energy Storage, and Portable Emergency Power.
1. KiloVault HLX Series
KiloVault HLX-Series Deep- Cycle Lithium Batteries offer a configurable approach to residential energy storage wants. The HLX Series can be utilized individually or in combination for 12, 24, or 48-volt methods, with storage capacities starting from 150 Amp-hours to 1,200 Amp-hours.
KiloVault HLX Series Features:
- Flexible – Works in 12, 24, or 48V configurations
- Gives You More- You can use the full battery’s capability, discharging it 100%
- Long-life- Even after discharging it completely 2000 instances, 80% of the capacity remains.
- Maintenance Free – No watering required, or cleansing of hazardous chemical compounds
- High Efficiency – Giving you up to 12% more use-able saved vitality
- Smart Investment – Lower cost per watt-hour/cycle and a longer lifespan than lead batteries
- Safer – No thermal run-away points as with other lithium applied sciences
- Heavy Duty -Takes as much as 150A of steady charging/discharging present, assembly the powerful calls for of significant inverters and chargers
- 7.5 Year Warranty
KiloVault HLX Series Product Specifications:
1200 HLX | 1800 HLX | 3600 HLX | |
---|---|---|---|
Battery Type | Li-FePO4 | Li-FePO4 | Li-FePO4 |
Rated Capacity | 1200Wh | 1800Wh | 3600Wh |
Rated Voltage | 12.8 V DC | 12.8 V DC | 12.8 V DC |
Nominal Amp-Hour Capacity | 100Ah | 150Ah | 300Ah |
Continuous Discharge Current | 100A | 150Ah | 150Ah |
Maximum Discharge Current | 100A | 150Ah | 200A for 30 min, 150A (steady) |
Max Charge Current | 80A | 150Ah | 150Ah |
Peak Discharge Current < 3 secs | 350A | 500A | 500A |
Dimensions | |||
Length | 12.5 in (318 mm) | 19.1 in (485 mm) | 20.5 in (520 mm) |
Width | 6.5 in (165 mm) | 6.7 in (170 mm) | 8.7 in (220 mm) |
Height | 8.5 in (215 mm) | 9.4 in (240 mm) | 10.6 in (269 mm) |
Battery Weight | 27 lbs (12.2 kg) | 41.7 lbs (18.9kg) | 84.4 lbs (38.3 kg) |
Shipping Weight | 30 lbs (13.6 kg) | 45.2 lbs (20.5kg) | 103.4 lbs (46.9 kg) |
KiloVault 1800 HLX
2. KiloVault RES-Q
KiloVault RES-Q Portable Emergency Power Unit includes a 1,200 Watt-Hour battery, charge controller, and inverter that may power a fridge and charge cell phones. The KiloVault RES-Q is designed to be charged by photovoltaic panels, a backup generator, or commonplace 120 VAC power, and can provide as much as 1200Wh of emergency backup power.
KiloVault RES-Q Features:
- 1500W Pure Sinewave Inverter
- 1200Wh KiloVault Lithium Battery
- 25A Solar Charge Controller
- Built-in AC Charger
- Liquid Crystal Display Status
- 2x 120V Outlets
- 1x 12V Cigarette Lighter Adapter
- Lead Acid Battery Expansion Port
KiloVault RES-Q Specifications:
1500 RES-Q | |
---|---|
Rated Energy Capacity (Watt Hours) | 1280 Wh |
DC Voltage Nominal | 12.8V |
Nominal Amp-Hour Capacity | 100 Ah |
Cycle Rating | 2500+ cycles @ 80% Depth of Discharge |
Minimum Charge Time | 2.5 Hours |
Charge Retention | 1 Year (85%) |
Integrated Inverter | 1500W steady output/120VAC pure sinewave/Slow begin feature protects inverter from over-current draw |
Maximum Charge Current | 15A @ 12V from AC or DC circuitry |
Maximum DC Output | 20A |
Operating Temperature | 23 – 111°F (-5 – 45°C) |
Surge Ratings | 3000W (5ms), Soft Start (for brief surges) |
Environmental Rating | Indoor rated only – not rated for wet, damp, snowy circumstances |
Expansion Port for External Battery | We highly advocate utilizing an LFP battery (ie. KiloVault). The RES-Q fully discharges the external battery, right down to 10.5V, earlier than switching to the inner battery. Completely discharging a lead-acid battery will doubtless damage it and completely cut back its capability. |
Warranty | 2 Year Limited |
Dimensions | |
Length | 18.9 in (480 mm) |
Width | 9.4 in (238 mm) |
Height | 15.7 in (400 mm) |
Weight | 61.7 lbs (28 kg) |
KiloVault RESQ 1500
KiloVault HLX Tips And FAQ
Is it good to insulate the KiloVault battery?
It’s the same with any kind of battery. Because batteries warmth up when they charge, for those who insulate the field they’re in, it should retain the warmth better and the batteries will stay warmer. But be sure to remove the insulation within the sizzling months, as overheated batteries may have a shorter life.
What is one of the best working and storage temperature for the KiloVault?
The optimal temperature vary total is 59 – 95°F (15 – 35°C). Full operating temperatures have to be larger than 32°F (O°C) and fewer than 133°F (45°C). Charging the battery beneath 32°F (0°C) will potentially injury it.
What are the beneficial charge controller/inverter settings?
We highly suggest setting the Bulk/Absorb voltage to *14.0V* for a 12V system (*28.0V* for 24V system, *56.0V* for 48V), float voltage of 13.8V (27.6V for 24V, 55.2V for 48V). Higher settings will scale back the *life* of the batteries. For the inverter low voltage cut-off we strongly recommend 12.0V *or increased* (24.0V, for 24V techniques, 48.0V for 48V programs). Limit the period of the soak up voltage period to 2 minutes if the charger is more than 100A, otherwise set to five minutes.
Are there any considerations when wiring the batteries in parallel?
Yes – for the HLX collection batteries, the maximum configuration is 4 parallel strings of 4 collection batteries (16). In addition, when adding one other parallel row of batteries to an existing one, it is important to maintain all parallel series strings within 0.2V of each other. Before adding a new row of batteries to an current one, charge all batteries to 100% first.
For the CHLX series batteries, a most of 4 batteries can be utilized in series or parallel, however NOT each. The CHLX are programmed in order that when they’re in parallel or sequence if one gets cold enough to start out heating, all of the CHLX in sequence or parallel will begin heating. This is to prevent extensively completely different power attracts and states of charge within the battery bank when some are heating and can’t charge, while others are heat sufficient to charge. As the communication between the CHLX occurs by the power cables, if connected this manner, this communication cannot take place.
Can I combine and match models or brands?
No – this isn’t good follow with any battery bank.
Should I do an equalization charge on the batteries?
No- much like AGM batteries, an equalization charge may damage them by overcharging them.
Are the batteries shipped totally charged, or do I have to charge them?
No – transport guidelines do not enable deep cycle batteries to be absolutely charged during shipment. **Before you place the batteries into operation they need to ALL be charged to exactly the identical voltage (choose a voltage between 14.0-14.4, V but be certain they’re *ALL* the same). This will make sure you start with a good charge across the battery bank. Suggested battery charger (cables not included with this charger however are available – use merchandise code ALTCC-6AWG-60RB). We do NOT counsel using the Iota IQ-LIFE PO Smart Charger accent for use with KiloVault batteries as a result of the charge voltage is just too excessive.
Can I do a constant trickle charge on the batteries?
Storing the batteries with a continuing small trickle charge is just not beneficial. Unlike lead-acid batteries, lithium iron phosphate batteries self-consume vitality at such a low fee (0.020 amps or about 6 Watt-hours/day), the battery could be simply over-charged if placed on a trickle charger. Over-charging the battery triggers the over-charge safety – shutting it down till the voltage goes down sufficient by itself. Once that happens the trickle charger would quickly increase the voltage up too excessive once once more. As a consequence, the fixed cycling of this circuitry will shorten the life of the complete battery.
Is it dangerous to overcharge or over-discharge the battery?
Yes, it will decrease the life of the battery. It’s advisable to never discharge or charge the battery to the purpose where it has to close down to guard itself.
View Complete KiloVault Product And Discount Price
Customer Reviews
Kilovault Review – I have been working my new system with the KiloVault 3600 HLX for two weeks and it works incredible. I’ve watched it put out 168 amps with no concern and solely a couple tenths drop in voltage while doing it and then instantly returns to the traditional 13. 3 volts.
I have seen it charge in a short time at 68 amps from my solar array. The solely subject I have had is that the BMS will put this battery on standby when my PV enter matches the load on the battery… all the system “pauses” inflicting the inverter to close off, the charge controller goes to rest, or to alarm and the 12-volt system goes useless for a couple of seconds… Be advised the battery can go on standby…