Kilovault Llc – KiloVault® is dedicated to offering revolutionary and reasonably priced renewable power options for residential and commercial purposes.
KiloVault® design, market, and promote vitality storage and power conversion products based mostly on leading-edge technologies, that cut back the price of entry for householders, and assist scale back the affect of humanity on the environment.
Kilovault Llc
KiloVault® has greater than 20 years of experience designing renewable vitality systems. Our founders and lead growth engineers have distinctive perception into the wants of the residential power. This is simply their newest idea to help prospects store the sun, and save the planet.
Product Overview
Kilovault Llc – KiloVault® Solar Energy Storage merchandise cowl a wide range of applications, together with Flexible Energy Storage, Wall-Mount Energy Storage, and Portable Emergency Power.
1. KiloVault HLX Series
KiloVault HLX-Series Deep- Cycle Lithium Batteries provide a configurable approach to residential vitality storage needs. The HLX Series can be used individually or together for 12, 24, or 48-volt systems, with storage capacities starting from 150 Amp-hours to 1,200 Amp-hours.
KiloVault HLX Series Features:
- Flexible – Works in 12, 24, or 48V configurations
- Gives You More- You can use the complete battery’s capacity, discharging it 100%
- Long-life- Even after discharging it completely 2000 times, 80% of the capability remains.
- Maintenance Free – No watering required, or cleaning of hazardous chemical compounds
- High Efficiency – Giving you up to 12% extra use-able stored vitality
- Smart Investment – Lower price per watt-hour/cycle and a longer lifespan than lead batteries
- Safer – No thermal run-away points as with other lithium technologies
- Heavy Duty -Takes up to 150A of continuous charging/discharging present, assembly the tough calls for of serious inverters and chargers
- 7.5 Year Warranty
KiloVault HLX Series Product Specifications:
1200 HLX | 1800 HLX | 3600 HLX | |
---|---|---|---|
Battery Type | Li-FePO4 | Li-FePO4 | Li-FePO4 |
Rated Capacity | 1200Wh | 1800Wh | 3600Wh |
Rated Voltage | 12.8 V DC | 12.8 V DC | 12.8 V DC |
Nominal Amp-Hour Capacity | 100Ah | 150Ah | 300Ah |
Continuous Discharge Current | 100A | 150Ah | 150Ah |
Maximum Discharge Current | 100A | 150Ah | 200A for 30 min, 150A (steady) |
Max Charge Current | 80A | 150Ah | 150Ah |
Peak Discharge Current < 3 secs | 350A | 500A | 500A |
Dimensions | |||
Length | 12.5 in (318 mm) | 19.1 in (485 mm) | 20.5 in (520 mm) |
Width | 6.5 in (165 mm) | 6.7 in (170 mm) | 8.7 in (220 mm) |
Height | 8.5 in (215 mm) | 9.4 in (240 mm) | 10.6 in (269 mm) |
Battery Weight | 27 lbs (12.2 kg) | 41.7 lbs (18.9kg) | 84.4 lbs (38.3 kg) |
Shipping Weight | 30 lbs (13.6 kg) | 45.2 lbs (20.5kg) | 103.4 lbs (46.9 kg) |
KiloVault 1800 HLX
2. KiloVault RES-Q
KiloVault RES-Q Portable Emergency Power Unit includes a 1,200 Watt-Hour battery, charge controller, and inverter that may power a fridge and charge cell telephones. The KiloVault RES-Q is designed to be charged by solar panels, a backup generator, or standard 120 VAC power, and can provide up to 1200Wh of emergency backup power.
KiloVault RES-Q Features:
- 1500W Pure Sinewave Inverter
- 1200Wh KiloVault Lithium Battery
- 25A Solar Charge Controller
- Built-in AC Charger
- Liquid Crystal Display Status
- 2x 120V Outlets
- 1x 12V Cigarette Lighter Adapter
- Lead Acid Battery Expansion Port
KiloVault RES-Q Specifications:
1500 RES-Q | |
---|---|
Rated Energy Capacity (Watt Hours) | 1280 Wh |
DC Voltage Nominal | 12.8V |
Nominal Amp-Hour Capacity | 100 Ah |
Cycle Rating | 2500+ cycles @ 80% Depth of Discharge |
Minimum Charge Time | 2.5 Hours |
Charge Retention | 1 Year (85%) |
Integrated Inverter | 1500W steady output/120VAC pure sinewave/Slow begin feature protects inverter from over-current draw |
Maximum Charge Current | 15A @ 12V from AC or DC circuitry |
Maximum DC Output | 20A |
Operating Temperature | 23 – 111°F (-5 – 45°C) |
Surge Ratings | 3000W (5ms), Soft Start (for brief surges) |
Environmental Rating | Indoor rated solely – not rated for wet, damp, snowy situations |
Expansion Port for External Battery | We extremely suggest utilizing an LFP battery (ie. KiloVault). The RES-Q fully discharges the exterior battery, right down to 10.5V, before switching to the inner battery. Completely discharging a lead-acid battery will doubtless injury it and completely reduce its capacity. |
Warranty | 2 Year Limited |
Dimensions | |
Length | 18.9 in (480 mm) |
Width | 9.4 in (238 mm) |
Height | 15.7 in (400 mm) |
Weight | 61.7 lbs (28 kg) |
KiloVault RESQ 1500
KiloVault HLX Tips And FAQ
Is it good to insulate the KiloVault battery?
It’s the same with any sort of battery. Because batteries warmth up after they charge, when you insulate the field they are in, it is going to retain the warmth higher and the batteries will stay hotter. But ensure that to take away the insulation in the hot months, as overheated batteries will have a shorter life.
What is the best operating and storage temperature for the KiloVault?
The optimum temperature vary overall is 59 – 95°F (15 – 35°C). Full operating temperatures have to be greater than 32°F (O°C) and fewer than 133°F (45°C). Charging the battery below 32°F (0°C) will potentially harm it.
What are the really helpful charge controller/inverter settings?
We extremely suggest setting the Bulk/Absorb voltage to *14.0V* for a 12V system (*28.0V* for 24V system, *56.0V* for 48V), float voltage of 13.8V (27.6V for 24V, 55.2V for 48V). Higher settings will scale back the *life* of the batteries. For the inverter low voltage cut-off we strongly advocate 12.0V *or larger* (24.0V, for 24V systems, 48.0V for 48V systems). Limit the period of the take in voltage period to 2 minutes if the charger is greater than 100A, in any other case set to 5 minutes.
Are there any concerns when wiring the batteries in parallel?
Yes – for the HLX collection batteries, the maximum configuration is 4 parallel strings of 4 collection batteries (16). In addition, when including one other parallel row of batteries to an present one, you will need to maintain all parallel series strings inside 0.2V of each other. Before adding a new row of batteries to an current one, charge all batteries to 100% first.
For the CHLX collection batteries, a maximum of 4 batteries can be used in sequence or parallel, however NOT both. The CHLX are programmed so that when they are in parallel or collection if one gets cold sufficient to begin heating, the entire CHLX in series or parallel will start heating. This is to prevent widely totally different power attracts and states of charge within the battery financial institution when some are heating and cannot charge, whereas others are warm sufficient to charge. As the communication between the CHLX occurs by way of the power cables, if connected this way, this communication can’t happen.
Can I combine and match models or brands?
No – this isn’t good practice with any battery bank.
Should I do an equalization charge on the batteries?
No- very like AGM batteries, an equalization charge could injury them by overcharging them.
Are the batteries shipped totally charged, or do I need to charge them?
No – shipping guidelines do not allow deep cycle batteries to be absolutely charged during shipment. **Before you set the batteries into operation they need to ALL be charged to exactly the identical voltage (select a voltage between 14.0-14.4, V however ensure that they’re *ALL* the same). This will ensure you start with an excellent charge across the battery financial institution. Suggested battery charger (cables not included with this charger but can be found – use item code ALTCC-6AWG-60RB). We do NOT suggest using the Iota IQ-LIFE PO Smart Charger accent for use with KiloVault batteries as a result of the charge voltage is just too excessive.
Can I do a constant trickle charge on the batteries?
Storing the batteries with a relentless small trickle charge just isn’t really useful. Unlike lead-acid batteries, lithium iron phosphate batteries self-consume energy at such a low charge (0.020 amps or about 6 Watt-hours/day), the battery could be easily over-charged if placed on a trickle charger. Over-charging the battery triggers the over-charge protection – shutting it down till the voltage goes down enough by itself. Once that occurs the trickle charger would quickly increase the voltage up too high once once more. As a result, the constant cycling of this circuitry will shorten the lifetime of all the battery.
Is it bad to overcharge or over-discharge the battery?
Yes, it will decrease the life of the battery. It’s really useful to never discharge or charge the battery to the point where it has to close down to protect itself.
View Complete KiloVault Product And Discount Price
Customer Reviews
Kilovault Llc – I’ve been running my new system with the KiloVault 3600 HLX for two weeks and it works improbable. I’ve watched it put out 168 amps with no subject and solely a pair tenths drop in voltage whereas doing it and then immediately returns to the normal 13. 3 volts.
I have seen it charge very quickly at 68 amps from my solar array. The solely subject I’ve had is that the BMS will put this battery on standby when my PV input matches the load on the battery… the entire system “pauses” inflicting the inverter to shut off, the charge controller goes to rest, or to alarm and the 12-volt system goes dead for a couple of seconds… Be advised the battery can go on standby…
View More KiloVault Helpful Reviews