Kilovault 2100 Plc Review

Kilovault Hab 48V 7.5Kwh Lithium Battery

Kilovault Hab 48V 7.5Kwh Lithium Battery – KiloVault® is devoted to providing progressive and affordable renewable energy solutions for residential and commercial functions.

KiloVault® design, market, and promote energy storage and power conversion merchandise primarily based on modern applied sciences, that reduce the price of entry for owners, and help scale back the impact of humanity on the setting.
Kilovault Hab 48V 7.5Kwh Lithium Battery

Kilovault Hab 48V 7.5Kwh Lithium Battery

KiloVault® has greater than 20 years of expertise designing renewable vitality methods. Our founders and lead growth engineers have unique insight into the wants of the residential power. This is just their latest thought to help prospects store the solar, and save the planet.

Product Overview

Kilovault Hab 48V 7.5Kwh Lithium Battery – KiloVault® Solar Energy Storage products cowl a wide range of purposes, including Flexible Energy Storage, Wall-Mount Energy Storage, and Portable Emergency Power.

1. KiloVault HLX Series

KiloVault HLX-Series Deep- Cycle Lithium Batteries supply a configurable approach to residential energy storage wants. The HLX Series can be utilized individually or together for 12, 24, or 48-volt methods, with storage capacities ranging from 150 Amp-hours to 1,200 Amp-hours.

KiloVault HLX Series Features:

  • Flexible – Works in 12, 24, or 48V configurations
  • Gives You More- You can use the total battery’s capability, discharging it 100%
  • Long-life- Even after discharging it fully 2000 occasions, 80% of the capability remains.
  • Maintenance Free – No watering required, or cleansing of hazardous chemical substances
  • High Efficiency – Giving you as much as 12% more use-able stored power
  • Smart Investment – Lower cost per watt-hour/cycle and an extended lifespan than lead batteries
  • Safer – No thermal run-away issues as with different lithium applied sciences
  • Heavy Duty -Takes up to 150A of continuous charging/discharging current, meeting the powerful calls for of great inverters and chargers
  • 7.5 Year Warranty

KiloVault HLX Series Product Specifications:

1200 HLX1800 HLX3600 HLX
Battery TypeLi-FePO4Li-FePO4Li-FePO4
Rated Capacity1200Wh1800Wh3600Wh
Rated Voltage12.8 V DC12.8 V DC12.8 V DC
Nominal Amp-Hour Capacity100Ah150Ah300Ah
Continuous Discharge Current100A150Ah150Ah
Maximum Discharge Current100A150Ah200A for 30 min, 150A (steady)
Max Charge Current80A150Ah150Ah
Peak Discharge Current < 3 secs350A500A500A
Dimensions
Length12.5 in (318 mm)19.1 in (485 mm)20.5 in (520 mm)
Width6.5 in (165 mm)6.7 in (170 mm)8.7 in (220 mm)
Height8.5 in (215 mm)9.4 in (240 mm)10.6 in (269 mm)
Battery Weight27 lbs (12.2 kg)41.7 lbs (18.9kg)84.4 lbs (38.3 kg)
Shipping Weight30 lbs (13.6 kg)45.2 lbs (20.5kg)103.4 lbs (46.9 kg)

KiloVault 1800 HLX

KiloVault 1800 HLX 1800Wh 12V
KiloVault 1800 HLX 1800Wh 12V
Price: $1,045.00
The KiloVault™ HLX series of solar lithium batteries were specifically designed and tested for the beating that serious hybrid and off-grid inverters and solar charge controllers can throw at it. Compared to traditional deep cycle batteries, the HLX Series’ lithium battery technology will more efficiently store and deliver the renewable energy you have generated, with no maintenance on your part.

2. KiloVault RES-Q

KiloVault RES-Q Portable Emergency Power Unit features a 1,200 Watt-Hour battery, charge controller, and inverter that may power a refrigerator and charge cell telephones. The KiloVault RES-Q is designed to be charged by photovoltaic panels, a backup generator, or normal 120 VAC energy, and can present up to 1200Wh of emergency backup power.

KiloVault RES-Q Features:

  • 1500W Pure Sinewave Inverter
  • 1200Wh KiloVault Lithium Battery
  • 25A Solar Charge Controller
  • Built-in AC Charger
  • Liquid Crystal Display Status
  • 2x 120V Outlets
  • 1x 12V Cigarette Lighter Adapter
  • Lead Acid Battery Expansion Port

KiloVault RES-Q Specifications:

1500 RES-Q
Rated Energy Capacity (Watt Hours)1280 Wh
DC Voltage Nominal12.8V
Nominal Amp-Hour Capacity100 Ah
Cycle Rating2500+ cycles @ 80% Depth of Discharge
Minimum Charge Time2.5 Hours
Charge Retention1 Year (85%)
Integrated Inverter1500W steady output/120VAC pure sinewave/Slow begin characteristic protects inverter from over-current draw
Maximum Charge Current15A @ 12V from AC or DC circuitry
Maximum DC Output20A
Operating Temperature23 – 111°F (-5 – 45°C)
Surge Ratings3000W (5ms), Soft Start (for short surges)
Environmental RatingIndoor rated only – not rated for rainy, damp, snowy circumstances
Expansion Port for External BatteryWe highly advocate using an LFP battery (ie. KiloVault). The RES-Q utterly discharges the exterior battery, right down to 10.5V, earlier than switching to the interior battery. Completely discharging a lead-acid battery will possible damage it and completely reduce its capacity.
Warranty2 Year Limited
Dimensions
Length18.9 in (480 mm)
Width9.4 in (238 mm)
Height15.7 in (400 mm)
Weight61.7 lbs (28 kg)

KiloVault RESQ 1500

KiloVault RESQ 1500
KiloVault 1800 HLX 1800Wh 12V
Price: $1,045.00
KiloVault’s RES-Q Kit 1500 is an all-in-one solar power system – that’s portable!. It was designed specifically to provide emergency backup power for your most critical household appliances and devices – such as lighting, fans, cellphone/tablet charging —and even your refrigerator!

KiloVault HLX Tips And FAQ

Is it good to insulate the KiloVault battery?
It’s the identical with any type of battery. Because batteries heat up once they charge, should you insulate the field they’re in, it’s going to retain the warmth higher and the batteries will keep warmer. But be sure that to remove the insulation within the hot months, as overheated batteries will have a shorter life.

What is the perfect operating and storage temperature for the KiloVault? 
The optimum temperature range total is 59 – 95°F (15 – 35°C).  Full operating temperatures should be larger than 32°F (O°C) and fewer than 133°F (45°C). Charging the battery below 32°F (0°C) will potentially harm it.

What are the beneficial charge controller/inverter settings?
We extremely advocate setting the Bulk/Absorb voltage to *14.0V* for a 12V system (*28.0V* for 24V system, *56.0V* for 48V), float voltage of 13.8V (27.6V for 24V, 55.2V for 48V). Higher settings will cut back the *life* of the batteries. For the inverter low voltage cut-off we strongly suggest 12.0V *or larger* (24.0V, for 24V systems, 48.0V for 48V methods). Limit the duration of the take up voltage period to 2 minutes if the charger is more than 100A, otherwise set to 5 minutes.

Are there any considerations when wiring the batteries in parallel?
Yes – for the HLX series batteries, the utmost configuration is 4 parallel strings of 4 collection batteries (16).  In addition, when including one other parallel row of batteries to an current one, it is very important preserve all parallel sequence strings inside 0.2V of one another. Before adding a brand new row of batteries to an existing one, charge all batteries to 100% first.

For the CHLX sequence batteries, a maximum of 4 batteries can be utilized in collection or parallel, but NOT each.  The CHLX are programmed in order that when they are in parallel or sequence if one will get cold sufficient to start out heating, all of the CHLX in series or parallel will begin heating.  This is to prevent extensively totally different energy attracts and states of charge within the battery bank when some are heating and cannot charge, while others are warm sufficient to charge.  As the communication between the CHLX occurs by way of the facility cables, if related this fashion, this communication can’t happen.

Can I combine and match models or manufacturers?
No – this is not good practice with any battery financial institution.

Should I do an equalization charge on the batteries?
No- much like AGM batteries, an equalization charge might damage them by overcharging them.

Are the batteries shipped totally charged, or do I need to charge them?

No – shipping guidelines don’t allow deep cycle batteries to be fully charged during shipment.  **Before you set the batteries into operation they must ALL be charged to exactly the identical voltage (choose a voltage between 14.0-14.4, V however be sure they are *ALL* the same).  This will ensure you begin with a good charge throughout the battery bank.  Suggested battery charger (cables not included with this charger however are available – use merchandise code ALTCC-6AWG-60RB).  We do NOT counsel using the Iota IQ-LIFE PO Smart Charger accent to be used with KiloVault batteries because the charge voltage is too high.

Can I do a continuing trickle charge on the batteries?
Storing the batteries with a continuing small trickle charge will not be really helpful. Unlike lead-acid batteries, lithium iron phosphate batteries self-consume vitality at such a low charge (0.020 amps or about 6 Watt-hours/day), the battery might be simply over-charged if put on a trickle charger. Over-charging the battery triggers the over-charge safety – shutting it down until the voltage goes down enough by itself. Once that occurs the trickle charger would rapidly increase the voltage up too excessive once again. As a outcome, the constant cycling of this circuitry will shorten the life of your complete battery.

Is it dangerous to overcharge or over-discharge the battery?
Yes, this may decrease the life of the battery. It’s really useful to by no means discharge or charge the battery to the purpose where it has to close down to protect itself.

View Complete KiloVault Product And Discount Price

Customer Reviews

Kilovault Hab 48V 7.5Kwh Lithium Battery – I have been running my new system with the KiloVault 3600 HLX for two weeks and it really works incredible. I’ve watched it put out 168 amps with no subject and only a couple tenths drop in voltage whereas doing it after which instantly returns to the conventional 13. 3 volts.

I’ve seen it charge in a short time at 68 amps from my solar array. The only challenge I have had is that the BMS will put this battery on standby when my PV input matches the load on the battery… your entire system “pauses” causing the inverter to close off, the charge controller goes to rest, or to alarm and the 12-volt system goes dead for a couple of seconds… Be advised the battery can go on standby…

View More KiloVault Helpful Reviews

Related Products


Leave a Reply

Your email address will not be published. Required fields are marked *

Media Partner


ecoflow-christmas