Kilovault Battery Manual – KiloVault® is devoted to providing progressive and inexpensive renewable energy solutions for residential and business applications.
KiloVault® design, market, and promote vitality storage and power conversion merchandise based mostly on modern technologies, that cut back the cost of entry for owners, and assist reduce the impression of humanity on the surroundings.
Kilovault Battery Manual
KiloVault® has greater than 20 years of expertise designing renewable vitality techniques. Our founders and lead development engineers have unique perception into the needs of the residential power. This is simply their latest concept to help clients store the solar, and save the planet.
Product Overview
Kilovault Battery Manual – KiloVault® Solar Energy Storage merchandise cover a variety of functions, including Flexible Energy Storage, Wall-Mount Energy Storage, and Portable Emergency Power.
1. KiloVault HLX Series
KiloVault HLX-Series Deep- Cycle Lithium Batteries supply a configurable approach to residential power storage wants. The HLX Series can be used individually or in combination for 12, 24, or 48-volt methods, with storage capacities starting from 150 Amp-hours to 1,200 Amp-hours.
KiloVault HLX Series Features:
- Flexible – Works in 12, 24, or 48V configurations
- Gives You More- You can use the complete battery’s capability, discharging it 100%
- Long-life- Even after discharging it fully 2000 times, 80% of the capacity stays.
- Maintenance Free – No watering required, or cleaning of hazardous chemical substances
- High Efficiency – Giving you as much as 12% extra use-able saved energy
- Smart Investment – Lower price per watt-hour/cycle and an extended lifespan than lead batteries
- Safer – No thermal run-away points as with different lithium technologies
- Heavy Duty -Takes as much as 150A of continuous charging/discharging present, meeting the powerful demands of significant inverters and chargers
- 7.5 Year Warranty
KiloVault HLX Series Product Specifications:
1200 HLX | 1800 HLX | 3600 HLX | |
---|---|---|---|
Battery Type | Li-FePO4 | Li-FePO4 | Li-FePO4 |
Rated Capacity | 1200Wh | 1800Wh | 3600Wh |
Rated Voltage | 12.8 V DC | 12.8 V DC | 12.8 V DC |
Nominal Amp-Hour Capacity | 100Ah | 150Ah | 300Ah |
Continuous Discharge Current | 100A | 150Ah | 150Ah |
Maximum Discharge Current | 100A | 150Ah | 200A for 30 min, 150A (steady) |
Max Charge Current | 80A | 150Ah | 150Ah |
Peak Discharge Current < 3 secs | 350A | 500A | 500A |
Dimensions | |||
Length | 12.5 in (318 mm) | 19.1 in (485 mm) | 20.5 in (520 mm) |
Width | 6.5 in (165 mm) | 6.7 in (170 mm) | 8.7 in (220 mm) |
Height | 8.5 in (215 mm) | 9.4 in (240 mm) | 10.6 in (269 mm) |
Battery Weight | 27 lbs (12.2 kg) | 41.7 lbs (18.9kg) | 84.4 lbs (38.3 kg) |
Shipping Weight | 30 lbs (13.6 kg) | 45.2 lbs (20.5kg) | 103.4 lbs (46.9 kg) |
KiloVault 1800 HLX
2. KiloVault RES-Q
KiloVault RES-Q Portable Emergency Power Unit includes a 1,200 Watt-Hour battery, charge controller, and inverter that may power a fridge and charge cell phones. The KiloVault RES-Q is designed to be charged by solar panels, a backup generator, or normal 120 VAC energy, and will provide up to 1200Wh of emergency backup power.
KiloVault RES-Q Features:
- 1500W Pure Sinewave Inverter
- 1200Wh KiloVault Lithium Battery
- 25A Solar Charge Controller
- Built-in AC Charger
- Liquid Crystal Display Status
- 2x 120V Outlets
- 1x 12V Cigarette Lighter Adapter
- Lead Acid Battery Expansion Port
KiloVault RES-Q Specifications:
1500 RES-Q | |
---|---|
Rated Energy Capacity (Watt Hours) | 1280 Wh |
DC Voltage Nominal | 12.8V |
Nominal Amp-Hour Capacity | 100 Ah |
Cycle Rating | 2500+ cycles @ 80% Depth of Discharge |
Minimum Charge Time | 2.5 Hours |
Charge Retention | 1 Year (85%) |
Integrated Inverter | 1500W continuous output/120VAC pure sinewave/Slow start function protects inverter from over-current draw |
Maximum Charge Current | 15A @ 12V from AC or DC circuitry |
Maximum DC Output | 20A |
Operating Temperature | 23 – 111°F (-5 – 45°C) |
Surge Ratings | 3000W (5ms), Soft Start (for brief surges) |
Environmental Rating | Indoor rated solely – not rated for wet, damp, snowy circumstances |
Expansion Port for External Battery | We extremely advocate using an LFP battery (ie. KiloVault). The RES-Q utterly discharges the external battery, down to 10.5V, earlier than switching to the inner battery. Completely discharging a lead-acid battery will doubtless injury it and permanently scale back its capacity. |
Warranty | 2 Year Limited |
Dimensions | |
Length | 18.9 in (480 mm) |
Width | 9.4 in (238 mm) |
Height | 15.7 in (400 mm) |
Weight | 61.7 lbs (28 kg) |
KiloVault RESQ 1500
KiloVault HLX Tips And FAQ
Is it good to insulate the KiloVault battery?
It’s the same with any kind of battery. Because batteries warmth up after they charge, should you insulate the field they are in, it is going to retain the heat better and the batteries will stay hotter. But make sure to remove the insulation in the scorching months, as overheated batteries can have a shorter life.
What is the perfect working and storage temperature for the KiloVault?
The optimum temperature vary total is 59 – 95°F (15 – 35°C). Full operating temperatures must be higher than 32°F (O°C) and fewer than 133°F (45°C). Charging the battery beneath 32°F (0°C) will doubtlessly harm it.
What are the really useful charge controller/inverter settings?
We highly suggest setting the Bulk/Absorb voltage to *14.0V* for a 12V system (*28.0V* for 24V system, *56.0V* for 48V), float voltage of 13.8V (27.6V for 24V, 55.2V for 48V). Higher settings will cut back the *life* of the batteries. For the inverter low voltage cut-off we strongly recommend 12.0V *or larger* (24.0V, for 24V systems, 48.0V for 48V techniques). Limit the length of the soak up voltage interval to 2 minutes if the charger is more than 100A, in any other case set to 5 minutes.
Are there any issues when wiring the batteries in parallel?
Yes – for the HLX sequence batteries, the utmost configuration is 4 parallel strings of 4 collection batteries (16). In addition, when adding one other parallel row of batteries to an current one, it is important to keep all parallel sequence strings within 0.2V of each other. Before including a brand new row of batteries to an current one, charge all batteries to 100% first.
For the CHLX collection batteries, a most of 4 batteries can be utilized in series or parallel, but NOT both. The CHLX are programmed so that when they are in parallel or sequence if one will get chilly enough to begin heating, the entire CHLX in collection or parallel will begin heating. This is to stop widely totally different power draws and states of charge in the battery financial institution when some are heating and cannot charge, whereas others are warm sufficient to charge. As the communication between the CHLX happens through the facility cables, if linked this fashion, this communication can’t happen.
Can I combine and match models or manufacturers?
No – this isn’t good practice with any battery financial institution.
Should I do an equalization charge on the batteries?
No- much like AGM batteries, an equalization charge might injury them by overcharging them.
Are the batteries shipped absolutely charged, or do I must charge them?
No – delivery guidelines do not enable deep cycle batteries to be totally charged during shipment. **Before you put the batteries into operation they must ALL be charged to exactly the same voltage (choose a voltage between 14.0-14.4, V however be certain they are *ALL* the identical). This will make sure you begin with an excellent charge across the battery bank. Suggested battery charger (cables not included with this charger but can be found – use merchandise code ALTCC-6AWG-60RB). We do NOT counsel using the Iota IQ-LIFE PO Smart Charger accent to be used with KiloVault batteries because the charge voltage is too excessive.
Can I do a relentless trickle charge on the batteries?
Storing the batteries with a continuing small trickle charge just isn’t advisable. Unlike lead-acid batteries, lithium iron phosphate batteries self-consume power at such a low fee (0.020 amps or about 6 Watt-hours/day), the battery may be simply over-charged if put on a trickle charger. Over-charging the battery triggers the over-charge safety – shutting it down until the voltage goes down enough by itself. Once that happens the trickle charger would rapidly raise the voltage up too excessive as soon as once more. As a end result, the fixed cycling of this circuitry will shorten the lifetime of your entire battery.
Is it dangerous to overcharge or over-discharge the battery?
Yes, this may lower the life of the battery. It’s advisable to by no means discharge or charge the battery to the point the place it has to close down to guard itself.
View Complete KiloVault Product And Discount Price
Customer Reviews
Kilovault Battery Manual – I have been running my new system with the KiloVault 3600 HLX for 2 weeks and it really works fantastic. I’ve watched it put out 168 amps with no situation and solely a couple tenths drop in voltage while doing it and then instantly returns to the traditional 13. 3 volts.
I have seen it charge in a short time at 68 amps from my solar array. The solely situation I have had is that the BMS will put this battery on standby when my PV enter matches the load on the battery… the whole system “pauses” causing the inverter to shut off, the charge controller goes to rest, or to alarm and the 12-volt system goes lifeless for a few seconds… Be suggested the battery can go on standby…
View More KiloVault Helpful Reviews