Kilovault Battery Manual – KiloVault® is dedicated to offering innovative and reasonably priced renewable vitality solutions for residential and industrial applications.
KiloVault® design, market, and sell vitality storage and energy conversion products based on leading-edge applied sciences, that scale back the cost of entry for owners, and assist scale back the impression of humanity on the atmosphere.
Kilovault Battery Manual
KiloVault® has more than 20 years of expertise designing renewable vitality techniques. Our founders and lead improvement engineers have distinctive perception into the wants of the residential energy. This is just their newest idea to assist prospects retailer the solar, and save the planet.
Product Overview
Kilovault Battery Manual – KiloVault® Solar Energy Storage merchandise cover a variety of applications, including Flexible Energy Storage, Wall-Mount Energy Storage, and Portable Emergency Power.
1. KiloVault HLX Series
KiloVault HLX-Series Deep- Cycle Lithium Batteries supply a configurable approach to residential vitality storage needs. The HLX Series can be used individually or in combination for 12, 24, or 48-volt methods, with storage capacities starting from 150 Amp-hours to 1,200 Amp-hours.
KiloVault HLX Series Features:
- Flexible – Works in 12, 24, or 48V configurations
- Gives You More- You can use the full battery’s capacity, discharging it 100%
- Long-life- Even after discharging it utterly 2000 instances, 80% of the capability remains.
- Maintenance Free – No watering required, or cleansing of hazardous chemicals
- High Efficiency – Giving you up to 12% extra use-able stored power
- Smart Investment – Lower price per watt-hour/cycle and an extended lifespan than lead batteries
- Safer – No thermal run-away issues as with other lithium technologies
- Heavy Duty -Takes up to 150A of continuous charging/discharging current, meeting the powerful calls for of significant inverters and chargers
- 7.5 Year Warranty
KiloVault HLX Series Product Specifications:
1200 HLX | 1800 HLX | 3600 HLX | |
---|---|---|---|
Battery Type | Li-FePO4 | Li-FePO4 | Li-FePO4 |
Rated Capacity | 1200Wh | 1800Wh | 3600Wh |
Rated Voltage | 12.8 V DC | 12.8 V DC | 12.8 V DC |
Nominal Amp-Hour Capacity | 100Ah | 150Ah | 300Ah |
Continuous Discharge Current | 100A | 150Ah | 150Ah |
Maximum Discharge Current | 100A | 150Ah | 200A for 30 min, 150A (continuous) |
Max Charge Current | 80A | 150Ah | 150Ah |
Peak Discharge Current < 3 secs | 350A | 500A | 500A |
Dimensions | |||
Length | 12.5 in (318 mm) | 19.1 in (485 mm) | 20.5 in (520 mm) |
Width | 6.5 in (165 mm) | 6.7 in (170 mm) | 8.7 in (220 mm) |
Height | 8.5 in (215 mm) | 9.4 in (240 mm) | 10.6 in (269 mm) |
Battery Weight | 27 lbs (12.2 kg) | 41.7 lbs (18.9kg) | 84.4 lbs (38.3 kg) |
Shipping Weight | 30 lbs (13.6 kg) | 45.2 lbs (20.5kg) | 103.4 lbs (46.9 kg) |
KiloVault 1800 HLX
2. KiloVault RES-Q
KiloVault RES-Q Portable Emergency Power Unit includes a 1,200 Watt-Hour battery, charge controller, and inverter that can power a fridge and charge cell phones. The KiloVault RES-Q is designed to be charged by photovoltaic panels, a backup generator, or commonplace 120 VAC power, and will present as much as 1200Wh of emergency backup power.
KiloVault RES-Q Features:
- 1500W Pure Sinewave Inverter
- 1200Wh KiloVault Lithium Battery
- 25A Solar Charge Controller
- Built-in AC Charger
- Liquid Crystal Display Status
- 2x 120V Outlets
- 1x 12V Cigarette Lighter Adapter
- Lead Acid Battery Expansion Port
KiloVault RES-Q Specifications:
1500 RES-Q | |
---|---|
Rated Energy Capacity (Watt Hours) | 1280 Wh |
DC Voltage Nominal | 12.8V |
Nominal Amp-Hour Capacity | 100 Ah |
Cycle Rating | 2500+ cycles @ 80% Depth of Discharge |
Minimum Charge Time | 2.5 Hours |
Charge Retention | 1 Year (85%) |
Integrated Inverter | 1500W steady output/120VAC pure sinewave/Slow begin feature protects inverter from over-current draw |
Maximum Charge Current | 15A @ 12V from AC or DC circuitry |
Maximum DC Output | 20A |
Operating Temperature | 23 – 111°F (-5 – 45°C) |
Surge Ratings | 3000W (5ms), Soft Start (for brief surges) |
Environmental Rating | Indoor rated solely – not rated for rainy, damp, snowy conditions |
Expansion Port for External Battery | We highly advocate utilizing an LFP battery (ie. KiloVault). The RES-Q completely discharges the exterior battery, down to 10.5V, earlier than switching to the inner battery. Completely discharging a lead-acid battery will possible harm it and completely reduce its capacity. |
Warranty | 2 Year Limited |
Dimensions | |
Length | 18.9 in (480 mm) |
Width | 9.4 in (238 mm) |
Height | 15.7 in (400 mm) |
Weight | 61.7 lbs (28 kg) |
KiloVault RESQ 1500
KiloVault HLX Tips And FAQ
Is it good to insulate the KiloVault battery?
It’s the identical with any type of battery. Because batteries warmth up once they charge, for those who insulate the box they are in, it is going to retain the warmth better and the batteries will stay warmer. But be certain that to remove the insulation within the scorching months, as overheated batteries will have a shorter life.
What is one of the best working and storage temperature for the KiloVault?
The optimum temperature vary general is 59 – 95°F (15 – 35°C). Full working temperatures should be greater than 32°F (O°C) and less than 133°F (45°C). Charging the battery beneath 32°F (0°C) will probably injury it.
What are the really helpful charge controller/inverter settings?
We highly suggest setting the Bulk/Absorb voltage to *14.0V* for a 12V system (*28.0V* for 24V system, *56.0V* for 48V), float voltage of 13.8V (27.6V for 24V, 55.2V for 48V). Higher settings will scale back the *life* of the batteries. For the inverter low voltage cut-off we strongly advocate 12.0V *or increased* (24.0V, for 24V techniques, 48.0V for 48V methods). Limit the duration of the take up voltage interval to 2 minutes if the charger is greater than 100A, otherwise set to five minutes.
Are there any issues when wiring the batteries in parallel?
Yes – for the HLX series batteries, the utmost configuration is 4 parallel strings of 4 sequence batteries (16). In addition, when including another parallel row of batteries to an existing one, it is important to preserve all parallel series strings inside 0.2V of one another. Before including a new row of batteries to an current one, charge all batteries to 100% first.
For the CHLX collection batteries, a most of 4 batteries can be utilized in sequence or parallel, however NOT each. The CHLX are programmed so that when they are in parallel or sequence if one will get cold sufficient to start heating, the entire CHLX in sequence or parallel will begin heating. This is to forestall extensively different power draws and states of charge in the battery financial institution when some are heating and can’t charge, while others are warm sufficient to charge. As the communication between the CHLX happens by way of the facility cables, if linked this way, this communication can not happen.
Can I mix and match models or manufacturers?
No – this is not good practice with any battery bank.
Should I do an equalization charge on the batteries?
No- very like AGM batteries, an equalization charge could harm them by overcharging them.
Are the batteries shipped absolutely charged, or do I need to charge them?
No – transport pointers don’t permit deep cycle batteries to be fully charged throughout cargo. **Before you place the batteries into operation they need to ALL be charged to precisely the same voltage (choose a voltage between 14.0-14.4, V however be certain that they’re *ALL* the same). This will make sure you start with an excellent charge across the battery financial institution. Suggested battery charger (cables not included with this charger however can be found – use item code ALTCC-6AWG-60RB). We do NOT counsel using the Iota IQ-LIFE PO Smart Charger accent to be used with KiloVault batteries because the charge voltage is too high.
Can I do a relentless trickle charge on the batteries?
Storing the batteries with a continuing small trickle charge is just not really useful. Unlike lead-acid batteries, lithium iron phosphate batteries self-consume power at such a low fee (0.020 amps or about 6 Watt-hours/day), the battery will be simply over-charged if placed on a trickle charger. Over-charging the battery triggers the over-charge safety – shutting it down until the voltage goes down enough by itself. Once that happens the trickle charger would rapidly elevate the voltage up too excessive once once more. As a outcome, the fixed biking of this circuitry will shorten the life of your entire battery.
Is it unhealthy to overcharge or over-discharge the battery?
Yes, this can lower the lifetime of the battery. It’s really useful to never discharge or charge the battery to the purpose the place it has to close down to guard itself.
View Complete KiloVault Product And Discount Price
Customer Reviews
Kilovault Battery Manual – I’ve been running my new system with the KiloVault 3600 HLX for 2 weeks and it really works unbelievable. I’ve watched it put out 168 amps with no subject and solely a couple tenths drop in voltage while doing it after which immediately returns to the conventional 13. 3 volts.
I have seen it charge very quickly at 68 amps from my solar array. The solely issue I have had is that the BMS will put this battery on standby when my PV input matches the load on the battery… the complete system “pauses” inflicting the inverter to close off, the charge controller goes to rest, or to alarm and the 12-volt system goes lifeless for a few seconds… Be suggested the battery can go on standby…
View More KiloVault Helpful Reviews