Kilovault 2100 Plc Review – KiloVault® is devoted to providing progressive and affordable renewable vitality options for residential and commercial applications.
KiloVault® design, market, and sell power storage and energy conversion products primarily based on modern technologies, that scale back the cost of entry for homeowners, and help cut back the affect of humanity on the atmosphere.
Kilovault 2100 Plc Review
KiloVault® has greater than 20 years of expertise designing renewable power techniques. Our founders and lead development engineers have unique perception into the needs of the residential energy. This is simply their latest idea to help prospects retailer the solar, and save the planet.
Product Overview
Kilovault 2100 Plc Review – KiloVault® Solar Energy Storage products cowl a variety of purposes, including Flexible Energy Storage, Wall-Mount Energy Storage, and Portable Emergency Power.
1. KiloVault HLX Series
KiloVault HLX-Series Deep- Cycle Lithium Batteries supply a configurable strategy to residential power storage wants. The HLX Series can be utilized individually or together for 12, 24, or 48-volt systems, with storage capacities ranging from 150 Amp-hours to 1,200 Amp-hours.
KiloVault HLX Series Features:
- Flexible – Works in 12, 24, or 48V configurations
- Gives You More- You can use the full battery’s capacity, discharging it 100%
- Long-life- Even after discharging it utterly 2000 instances, 80% of the capability stays.
- Maintenance Free – No watering required, or cleaning of hazardous chemicals
- High Efficiency – Giving you up to 12% more use-able saved vitality
- Smart Investment – Lower price per watt-hour/cycle and an extended lifespan than lead batteries
- Safer – No thermal run-away issues as with different lithium technologies
- Heavy Duty -Takes as much as 150A of steady charging/discharging present, assembly the powerful demands of serious inverters and chargers
- 7.5 Year Warranty
KiloVault HLX Series Product Specifications:
1200 HLX | 1800 HLX | 3600 HLX | |
---|---|---|---|
Battery Type | Li-FePO4 | Li-FePO4 | Li-FePO4 |
Rated Capacity | 1200Wh | 1800Wh | 3600Wh |
Rated Voltage | 12.8 V DC | 12.8 V DC | 12.8 V DC |
Nominal Amp-Hour Capacity | 100Ah | 150Ah | 300Ah |
Continuous Discharge Current | 100A | 150Ah | 150Ah |
Maximum Discharge Current | 100A | 150Ah | 200A for 30 min, 150A (steady) |
Max Charge Current | 80A | 150Ah | 150Ah |
Peak Discharge Current < 3 secs | 350A | 500A | 500A |
Dimensions | |||
Length | 12.5 in (318 mm) | 19.1 in (485 mm) | 20.5 in (520 mm) |
Width | 6.5 in (165 mm) | 6.7 in (170 mm) | 8.7 in (220 mm) |
Height | 8.5 in (215 mm) | 9.4 in (240 mm) | 10.6 in (269 mm) |
Battery Weight | 27 lbs (12.2 kg) | 41.7 lbs (18.9kg) | 84.4 lbs (38.3 kg) |
Shipping Weight | 30 lbs (13.6 kg) | 45.2 lbs (20.5kg) | 103.4 lbs (46.9 kg) |
KiloVault 1800 HLX
2. KiloVault RES-Q
KiloVault RES-Q Portable Emergency Power Unit includes a 1,200 Watt-Hour battery, charge controller, and inverter that can power a refrigerator and charge cell phones. The KiloVault RES-Q is designed to be charged by solar panels, a backup generator, or standard 120 VAC power, and will provide up to 1200Wh of emergency backup power.
KiloVault RES-Q Features:
- 1500W Pure Sinewave Inverter
- 1200Wh KiloVault Lithium Battery
- 25A Solar Charge Controller
- Built-in AC Charger
- Liquid Crystal Display Status
- 2x 120V Outlets
- 1x 12V Cigarette Lighter Adapter
- Lead Acid Battery Expansion Port
KiloVault RES-Q Specifications:
1500 RES-Q | |
---|---|
Rated Energy Capacity (Watt Hours) | 1280 Wh |
DC Voltage Nominal | 12.8V |
Nominal Amp-Hour Capacity | 100 Ah |
Cycle Rating | 2500+ cycles @ 80% Depth of Discharge |
Minimum Charge Time | 2.5 Hours |
Charge Retention | 1 Year (85%) |
Integrated Inverter | 1500W steady output/120VAC pure sinewave/Slow start feature protects inverter from over-current draw |
Maximum Charge Current | 15A @ 12V from AC or DC circuitry |
Maximum DC Output | 20A |
Operating Temperature | 23 – 111°F (-5 – 45°C) |
Surge Ratings | 3000W (5ms), Soft Start (for short surges) |
Environmental Rating | Indoor rated solely – not rated for rainy, damp, snowy circumstances |
Expansion Port for External Battery | We highly advocate utilizing an LFP battery (ie. KiloVault). The RES-Q completely discharges the exterior battery, all the way down to 10.5V, earlier than switching to the internal battery. Completely discharging a lead-acid battery will doubtless harm it and permanently reduce its capability. |
Warranty | 2 Year Limited |
Dimensions | |
Length | 18.9 in (480 mm) |
Width | 9.4 in (238 mm) |
Height | 15.7 in (400 mm) |
Weight | 61.7 lbs (28 kg) |
KiloVault RESQ 1500
KiloVault HLX Tips And FAQ
Is it good to insulate the KiloVault battery?
It’s the identical with any kind of battery. Because batteries warmth up after they charge, in case you insulate the box they are in, it will retain the heat better and the batteries will keep hotter. But make sure that to remove the insulation within the scorching months, as overheated batteries will have a shorter life.
What is the perfect working and storage temperature for the KiloVault?
The optimal temperature vary total is 59 – 95°F (15 – 35°C). Full working temperatures must be greater than 32°F (O°C) and less than 133°F (45°C). Charging the battery under 32°F (0°C) will probably injury it.
What are the beneficial charge controller/inverter settings?
We extremely suggest setting the Bulk/Absorb voltage to *14.0V* for a 12V system (*28.0V* for 24V system, *56.0V* for 48V), float voltage of 13.8V (27.6V for 24V, 55.2V for 48V). Higher settings will reduce the *life* of the batteries. For the inverter low voltage cut-off we strongly suggest 12.0V *or increased* (24.0V, for 24V techniques, 48.0V for 48V methods). Limit the duration of the take up voltage period to 2 minutes if the charger is greater than 100A, in any other case set to five minutes.
Are there any concerns when wiring the batteries in parallel?
Yes – for the HLX series batteries, the maximum configuration is 4 parallel strings of 4 sequence batteries (16). In addition, when adding one other parallel row of batteries to an current one, you will need to preserve all parallel series strings within 0.2V of each other. Before adding a new row of batteries to an present one, charge all batteries to 100% first.
For the CHLX series batteries, a most of 4 batteries can be used in series or parallel, but NOT both. The CHLX are programmed so that when they’re in parallel or sequence if one gets cold enough to start heating, the entire CHLX in series or parallel will begin heating. This is to forestall widely totally different power draws and states of charge in the battery bank when some are heating and cannot charge, whereas others are warm enough to charge. As the communication between the CHLX happens by the ability cables, if connected this way, this communication can’t happen.
Can I mix and match models or brands?
No – this isn’t good follow with any battery bank.
Should I do an equalization charge on the batteries?
No- much like AGM batteries, an equalization charge may damage them by overcharging them.
Are the batteries shipped fully charged, or do I must charge them?
No – transport tips don’t allow deep cycle batteries to be totally charged throughout cargo. **Before you put the batteries into operation they need to ALL be charged to precisely the same voltage (choose a voltage between 14.0-14.4, V but be certain that they are *ALL* the same). This will ensure you start with a good charge across the battery bank. Suggested battery charger (cables not included with this charger but are available – use merchandise code ALTCC-6AWG-60RB). We do NOT counsel using the Iota IQ-LIFE PO Smart Charger accessory to be used with KiloVault batteries because the charge voltage is simply too high.
Can I do a continuing trickle charge on the batteries?
Storing the batteries with a relentless small trickle charge just isn’t really useful. Unlike lead-acid batteries, lithium iron phosphate batteries self-consume vitality at such a low price (0.020 amps or about 6 Watt-hours/day), the battery might be simply over-charged if put on a trickle charger. Over-charging the battery triggers the over-charge safety – shutting it down till the voltage goes down enough by itself. Once that happens the trickle charger would shortly raise the voltage up too high as soon as once more. As a result, the fixed cycling of this circuitry will shorten the lifetime of all the battery.
Is it bad to overcharge or over-discharge the battery?
Yes, this will lower the life of the battery. It’s recommended to by no means discharge or charge the battery to the purpose where it has to shut down to guard itself.
View Complete KiloVault Product And Discount Price
Customer Reviews
Kilovault 2100 Plc Review – I’ve been running my new system with the KiloVault 3600 HLX for two weeks and it really works implausible. I’ve watched it put out 168 amps with no challenge and solely a couple tenths drop in voltage while doing it after which instantly returns to the traditional 13. 3 volts.
I have seen it charge in a short time at 68 amps from my solar array. The only difficulty I’ve had is that the BMS will put this battery on standby when my PV input matches the load on the battery… your complete system “pauses” inflicting the inverter to shut off, the charge controller goes to relaxation, or to alarm and the 12-volt system goes dead for a couple of seconds… Be suggested the battery can go on standby…
View More KiloVault Helpful Reviews