Kilovault 1800 Chlx Price – KiloVault® is dedicated to providing progressive and affordable renewable vitality solutions for residential and industrial functions.
KiloVault® design, market, and sell vitality storage and energy conversion products primarily based on modern technologies, that cut back the cost of entry for householders, and assist reduce the affect of humanity on the atmosphere.
Kilovault 1800 Chlx Price
KiloVault® has more than 20 years of experience designing renewable energy techniques. Our founders and lead development engineers have distinctive perception into the needs of the residential energy. This is just their latest idea to assist customers retailer the sun, and save the planet.
Product Overview
Kilovault 1800 Chlx Price – KiloVault® Solar Energy Storage merchandise cowl a wide range of functions, including Flexible Energy Storage, Wall-Mount Energy Storage, and Portable Emergency Power.
1. KiloVault HLX Series
KiloVault HLX-Series Deep- Cycle Lithium Batteries offer a configurable method to residential energy storage needs. The HLX Series can be used individually or together for 12, 24, or 48-volt methods, with storage capacities starting from 150 Amp-hours to 1,200 Amp-hours.
KiloVault HLX Series Features:
- Flexible – Works in 12, 24, or 48V configurations
- Gives You More- You can use the full battery’s capacity, discharging it 100%
- Long-life- Even after discharging it completely 2000 instances, 80% of the capacity stays.
- Maintenance Free – No watering required, or cleaning of hazardous chemical substances
- High Efficiency – Giving you up to 12% more use-able saved vitality
- Smart Investment – Lower cost per watt-hour/cycle and a longer lifespan than lead batteries
- Safer – No thermal run-away points as with different lithium applied sciences
- Heavy Duty -Takes up to 150A of continuous charging/discharging current, meeting the powerful demands of significant inverters and chargers
- 7.5 Year Warranty
KiloVault HLX Series Product Specifications:
1200 HLX | 1800 HLX | 3600 HLX | |
---|---|---|---|
Battery Type | Li-FePO4 | Li-FePO4 | Li-FePO4 |
Rated Capacity | 1200Wh | 1800Wh | 3600Wh |
Rated Voltage | 12.8 V DC | 12.8 V DC | 12.8 V DC |
Nominal Amp-Hour Capacity | 100Ah | 150Ah | 300Ah |
Continuous Discharge Current | 100A | 150Ah | 150Ah |
Maximum Discharge Current | 100A | 150Ah | 200A for 30 min, 150A (continuous) |
Max Charge Current | 80A | 150Ah | 150Ah |
Peak Discharge Current < 3 secs | 350A | 500A | 500A |
Dimensions | |||
Length | 12.5 in (318 mm) | 19.1 in (485 mm) | 20.5 in (520 mm) |
Width | 6.5 in (165 mm) | 6.7 in (170 mm) | 8.7 in (220 mm) |
Height | 8.5 in (215 mm) | 9.4 in (240 mm) | 10.6 in (269 mm) |
Battery Weight | 27 lbs (12.2 kg) | 41.7 lbs (18.9kg) | 84.4 lbs (38.3 kg) |
Shipping Weight | 30 lbs (13.6 kg) | 45.2 lbs (20.5kg) | 103.4 lbs (46.9 kg) |
KiloVault 1800 HLX
2. KiloVault RES-Q
KiloVault RES-Q Portable Emergency Power Unit includes a 1,200 Watt-Hour battery, charge controller, and inverter that may power a fridge and charge cell telephones. The KiloVault RES-Q is designed to be charged by photovoltaic panels, a backup generator, or customary 120 VAC power, and can provide up to 1200Wh of emergency backup energy.
KiloVault RES-Q Features:
- 1500W Pure Sinewave Inverter
- 1200Wh KiloVault Lithium Battery
- 25A Solar Charge Controller
- Built-in AC Charger
- Liquid Crystal Display Status
- 2x 120V Outlets
- 1x 12V Cigarette Lighter Adapter
- Lead Acid Battery Expansion Port
KiloVault RES-Q Specifications:
1500 RES-Q | |
---|---|
Rated Energy Capacity (Watt Hours) | 1280 Wh |
DC Voltage Nominal | 12.8V |
Nominal Amp-Hour Capacity | 100 Ah |
Cycle Rating | 2500+ cycles @ 80% Depth of Discharge |
Minimum Charge Time | 2.5 Hours |
Charge Retention | 1 Year (85%) |
Integrated Inverter | 1500W steady output/120VAC pure sinewave/Slow begin characteristic protects inverter from over-current draw |
Maximum Charge Current | 15A @ 12V from AC or DC circuitry |
Maximum DC Output | 20A |
Operating Temperature | 23 – 111°F (-5 – 45°C) |
Surge Ratings | 3000W (5ms), Soft Start (for short surges) |
Environmental Rating | Indoor rated only – not rated for wet, damp, snowy circumstances |
Expansion Port for External Battery | We extremely advocate utilizing an LFP battery (ie. KiloVault). The RES-Q completely discharges the exterior battery, all the way down to 10.5V, before switching to the internal battery. Completely discharging a lead-acid battery will doubtless damage it and completely reduce its capacity. |
Warranty | 2 Year Limited |
Dimensions | |
Length | 18.9 in (480 mm) |
Width | 9.4 in (238 mm) |
Height | 15.7 in (400 mm) |
Weight | 61.7 lbs (28 kg) |
KiloVault RESQ 1500
KiloVault HLX Tips And FAQ
Is it good to insulate the KiloVault battery?
It’s the identical with any type of battery. Because batteries heat up after they charge, if you happen to insulate the box they’re in, it’ll retain the heat higher and the batteries will stay hotter. But make certain to take away the insulation within the hot months, as overheated batteries could have a shorter life.
What is the best operating and storage temperature for the KiloVault?
The optimum temperature range overall is 59 – 95°F (15 – 35°C). Full operating temperatures should be better than 32°F (O°C) and fewer than 133°F (45°C). Charging the battery under 32°F (0°C) will potentially harm it.
What are the beneficial charge controller/inverter settings?
We extremely suggest setting the Bulk/Absorb voltage to *14.0V* for a 12V system (*28.0V* for 24V system, *56.0V* for 48V), float voltage of 13.8V (27.6V for 24V, 55.2V for 48V). Higher settings will reduce the *life* of the batteries. For the inverter low voltage cut-off we strongly advocate 12.0V *or greater* (24.0V, for 24V methods, 48.0V for 48V techniques). Limit the duration of the absorb voltage period to 2 minutes if the charger is greater than 100A, in any other case set to 5 minutes.
Are there any considerations when wiring the batteries in parallel?
Yes – for the HLX collection batteries, the maximum configuration is 4 parallel strings of 4 sequence batteries (16). In addition, when adding another parallel row of batteries to an existing one, you will need to preserve all parallel collection strings inside 0.2V of one another. Before adding a new row of batteries to an current one, charge all batteries to 100% first.
For the CHLX collection batteries, a most of 4 batteries can be used in collection or parallel, however NOT each. The CHLX are programmed so that when they’re in parallel or collection if one will get chilly enough to start heating, the entire CHLX in sequence or parallel will begin heating. This is to forestall widely different energy attracts and states of charge in the battery financial institution when some are heating and can’t charge, while others are warm enough to charge. As the communication between the CHLX happens by way of the ability cables, if linked this way, this communication can’t happen.
Can I mix and match models or brands?
No – this isn’t good observe with any battery bank.
Should I do an equalization charge on the batteries?
No- very similar to AGM batteries, an equalization charge may damage them by overcharging them.
Are the batteries shipped absolutely charged, or do I need to charge them?
No – transport pointers don’t allow deep cycle batteries to be fully charged during shipment. **Before you place the batteries into operation they must ALL be charged to exactly the same voltage (select a voltage between 14.0-14.4, V but be certain they are *ALL* the identical). This will ensure you start with a fair charge throughout the battery financial institution. Suggested battery charger (cables not included with this charger however are available – use merchandise code ALTCC-6AWG-60RB). We do NOT counsel utilizing the Iota IQ-LIFE PO Smart Charger accessory to be used with KiloVault batteries as a result of the charge voltage is just too excessive.
Can I do a relentless trickle charge on the batteries?
Storing the batteries with a relentless small trickle charge shouldn’t be really useful. Unlike lead-acid batteries, lithium iron phosphate batteries self-consume power at such a low price (0.020 amps or about 6 Watt-hours/day), the battery might be easily over-charged if placed on a trickle charger. Over-charging the battery triggers the over-charge protection – shutting it down till the voltage goes down enough by itself. Once that occurs the trickle charger would rapidly elevate the voltage up too excessive as soon as again. As a end result, the constant cycling of this circuitry will shorten the life of your entire battery.
Is it dangerous to overcharge or over-discharge the battery?
Yes, this will lower the lifetime of the battery. It’s beneficial to never discharge or charge the battery to the point the place it has to close down to protect itself.
View Complete KiloVault Product And Discount Price
Customer Reviews
Kilovault 1800 Chlx Price – I’ve been working my new system with the KiloVault 3600 HLX for 2 weeks and it works incredible. I’ve watched it put out 168 amps with no difficulty and only a pair tenths drop in voltage while doing it and then immediately returns to the conventional 13. 3 volts.
I’ve seen it charge very quickly at 68 amps from my photovoltaic array. The solely difficulty I’ve had is that the BMS will put this battery on standby when my PV input matches the load on the battery… all the system “pauses” causing the inverter to shut off, the charge controller goes to rest, or to alarm and the 12-volt system goes lifeless for a couple of seconds… Be suggested the battery can go on standby…
View More KiloVault Helpful Reviews