Kilovault Reviews – KiloVault® is devoted to offering modern and reasonably priced renewable power options for residential and industrial functions.
KiloVault® design, market, and sell vitality storage and power conversion products based on leading-edge applied sciences, that cut back the cost of entry for homeowners, and assist cut back the affect of humanity on the atmosphere.
Kilovault Reviews
KiloVault® has greater than 20 years of experience designing renewable energy systems. Our founders and lead development engineers have distinctive perception into the wants of the residential energy. This is just their newest idea to help prospects retailer the solar, and save the planet.
Product Overview
Kilovault Reviews – KiloVault® Solar Energy Storage merchandise cover a wide range of applications, including Flexible Energy Storage, Wall-Mount Energy Storage, and Portable Emergency Power.
1. KiloVault HLX Series
KiloVault HLX-Series Deep- Cycle Lithium Batteries provide a configurable strategy to residential energy storage needs. The HLX Series can be used individually or in combination for 12, 24, or 48-volt techniques, with storage capacities ranging from 150 Amp-hours to 1,200 Amp-hours.
KiloVault HLX Series Features:
- Flexible – Works in 12, 24, or 48V configurations
- Gives You More- You can use the total battery’s capacity, discharging it 100%
- Long-life- Even after discharging it utterly 2000 occasions, 80% of the capability stays.
- Maintenance Free – No watering required, or cleansing of hazardous chemical compounds
- High Efficiency – Giving you as much as 12% extra use-able stored vitality
- Smart Investment – Lower price per watt-hour/cycle and an extended lifespan than lead batteries
- Safer – No thermal run-away points as with other lithium technologies
- Heavy Duty -Takes up to 150A of continuous charging/discharging current, assembly the powerful demands of serious inverters and chargers
- 7.5 Year Warranty
KiloVault HLX Series Product Specifications:
1200 HLX | 1800 HLX | 3600 HLX | |
---|---|---|---|
Battery Type | Li-FePO4 | Li-FePO4 | Li-FePO4 |
Rated Capacity | 1200Wh | 1800Wh | 3600Wh |
Rated Voltage | 12.8 V DC | 12.8 V DC | 12.8 V DC |
Nominal Amp-Hour Capacity | 100Ah | 150Ah | 300Ah |
Continuous Discharge Current | 100A | 150Ah | 150Ah |
Maximum Discharge Current | 100A | 150Ah | 200A for 30 min, 150A (steady) |
Max Charge Current | 80A | 150Ah | 150Ah |
Peak Discharge Current < 3 secs | 350A | 500A | 500A |
Dimensions | |||
Length | 12.5 in (318 mm) | 19.1 in (485 mm) | 20.5 in (520 mm) |
Width | 6.5 in (165 mm) | 6.7 in (170 mm) | 8.7 in (220 mm) |
Height | 8.5 in (215 mm) | 9.4 in (240 mm) | 10.6 in (269 mm) |
Battery Weight | 27 lbs (12.2 kg) | 41.7 lbs (18.9kg) | 84.4 lbs (38.3 kg) |
Shipping Weight | 30 lbs (13.6 kg) | 45.2 lbs (20.5kg) | 103.4 lbs (46.9 kg) |
KiloVault 1800 HLX
2. KiloVault RES-Q
KiloVault RES-Q Portable Emergency Power Unit includes a 1,200 Watt-Hour battery, charge controller, and inverter that may energy a refrigerator and charge cell phones. The KiloVault RES-Q is designed to be charged by solar panels, a backup generator, or customary 120 VAC power, and will present as much as 1200Wh of emergency backup energy.
KiloVault RES-Q Features:
- 1500W Pure Sinewave Inverter
- 1200Wh KiloVault Lithium Battery
- 25A Solar Charge Controller
- Built-in AC Charger
- Liquid Crystal Display Status
- 2x 120V Outlets
- 1x 12V Cigarette Lighter Adapter
- Lead Acid Battery Expansion Port
KiloVault RES-Q Specifications:
1500 RES-Q | |
---|---|
Rated Energy Capacity (Watt Hours) | 1280 Wh |
DC Voltage Nominal | 12.8V |
Nominal Amp-Hour Capacity | 100 Ah |
Cycle Rating | 2500+ cycles @ 80% Depth of Discharge |
Minimum Charge Time | 2.5 Hours |
Charge Retention | 1 Year (85%) |
Integrated Inverter | 1500W steady output/120VAC pure sinewave/Slow start function protects inverter from over-current draw |
Maximum Charge Current | 15A @ 12V from AC or DC circuitry |
Maximum DC Output | 20A |
Operating Temperature | 23 – 111°F (-5 – 45°C) |
Surge Ratings | 3000W (5ms), Soft Start (for short surges) |
Environmental Rating | Indoor rated solely – not rated for wet, damp, snowy conditions |
Expansion Port for External Battery | We extremely advocate using an LFP battery (ie. KiloVault). The RES-Q fully discharges the external battery, down to 10.5V, before switching to the internal battery. Completely discharging a lead-acid battery will likely damage it and completely scale back its capability. |
Warranty | 2 Year Limited |
Dimensions | |
Length | 18.9 in (480 mm) |
Width | 9.4 in (238 mm) |
Height | 15.7 in (400 mm) |
Weight | 61.7 lbs (28 kg) |
KiloVault RESQ 1500
KiloVault HLX Tips And FAQ
Is it good to insulate the KiloVault battery?
It’s the identical with any type of battery. Because batteries heat up when they charge, when you insulate the box they’re in, it’s going to retain the heat better and the batteries will stay hotter. But be sure that to remove the insulation in the scorching months, as overheated batteries will have a shorter life.
What is the perfect working and storage temperature for the KiloVault?
The optimal temperature vary total is 59 – 95°F (15 – 35°C). Full operating temperatures must be larger than 32°F (O°C) and fewer than 133°F (45°C). Charging the battery below 32°F (0°C) will probably harm it.
What are the really helpful charge controller/inverter settings?
We highly recommend setting the Bulk/Absorb voltage to *14.0V* for a 12V system (*28.0V* for 24V system, *56.0V* for 48V), float voltage of 13.8V (27.6V for 24V, 55.2V for 48V). Higher settings will scale back the *life* of the batteries. For the inverter low voltage cut-off we strongly suggest 12.0V *or greater* (24.0V, for 24V programs, 48.0V for 48V programs). Limit the period of the absorb voltage period to 2 minutes if the charger is more than 100A, in any other case set to five minutes.
Are there any considerations when wiring the batteries in parallel?
Yes – for the HLX series batteries, the utmost configuration is 4 parallel strings of 4 series batteries (16). In addition, when adding one other parallel row of batteries to an existing one, you will need to preserve all parallel collection strings inside 0.2V of one another. Before adding a new row of batteries to an current one, charge all batteries to 100% first.
For the CHLX collection batteries, a most of 4 batteries can be used in series or parallel, but NOT each. The CHLX are programmed in order that when they are in parallel or sequence if one will get cold sufficient to begin heating, all of the CHLX in series or parallel will start heating. This is to prevent broadly completely different power attracts and states of charge within the battery financial institution when some are heating and can’t charge, while others are warm sufficient to charge. As the communication between the CHLX happens by the ability cables, if linked this manner, this communication can not happen.
Can I combine and match models or manufacturers?
No – this is not good observe with any battery bank.
Should I do an equalization charge on the batteries?
No- very like AGM batteries, an equalization charge may injury them by overcharging them.
Are the batteries shipped totally charged, or do I must charge them?
No – transport pointers don’t permit deep cycle batteries to be absolutely charged during shipment. **Before you put the batteries into operation they need to ALL be charged to precisely the identical voltage (choose a voltage between 14.0-14.4, V but make sure that they’re *ALL* the identical). This will ensure you begin with an even charge throughout the battery bank. Suggested battery charger (cables not included with this charger however are available – use merchandise code ALTCC-6AWG-60RB). We do NOT suggest using the Iota IQ-LIFE PO Smart Charger accessory to be used with KiloVault batteries as a result of the charge voltage is just too excessive.
Can I do a constant trickle charge on the batteries?
Storing the batteries with a relentless small trickle charge shouldn’t be really helpful. Unlike lead-acid batteries, lithium iron phosphate batteries self-consume power at such a low price (0.020 amps or about 6 Watt-hours/day), the battery may be easily over-charged if placed on a trickle charger. Over-charging the battery triggers the over-charge protection – shutting it down till the voltage goes down sufficient by itself. Once that occurs the trickle charger would quickly increase the voltage up too high once once more. As a consequence, the fixed biking of this circuitry will shorten the lifetime of your complete battery.
Is it bad to overcharge or over-discharge the battery?
Yes, this will decrease the life of the battery. It’s recommended to by no means discharge or charge the battery to the point where it has to shut down to guard itself.
View Complete KiloVault Product And Discount Price
Customer Reviews
Kilovault Reviews – I’ve been running my new system with the KiloVault 3600 HLX for two weeks and it really works unbelievable. I’ve watched it put out 168 amps with no concern and only a pair tenths drop in voltage whereas doing it and then immediately returns to the traditional 13. 3 volts.
I’ve seen it charge very quickly at 68 amps from my solar array. The only issue I’ve had is that the BMS will put this battery on standby when my PV enter matches the load on the battery… the whole system “pauses” inflicting the inverter to close off, the charge controller goes to relaxation, or to alarm and the 12-volt system goes dead for a couple of seconds… Be suggested the battery can go on standby…
View More KiloVault Helpful Reviews