Kilo Volt Amps – KiloVault® is dedicated to providing progressive and inexpensive renewable energy options for residential and commercial purposes.
KiloVault® design, market, and promote energy storage and energy conversion products based on modern technologies, that reduce the cost of entry for homeowners, and assist reduce the influence of humanity on the environment.
Kilo Volt Amps
KiloVault® has more than 20 years of expertise designing renewable energy programs. Our founders and lead growth engineers have unique perception into the wants of the residential energy. This is just their latest concept to help clients retailer the sun, and save the planet.
Product Overview
Kilo Volt Amps – KiloVault® Solar Energy Storage merchandise cover a wide range of functions, including Flexible Energy Storage, Wall-Mount Energy Storage, and Portable Emergency Power.
1. KiloVault HLX Series
KiloVault HLX-Series Deep- Cycle Lithium Batteries supply a configurable approach to residential power storage wants. The HLX Series can be used individually or together for 12, 24, or 48-volt programs, with storage capacities ranging from 150 Amp-hours to 1,200 Amp-hours.
KiloVault HLX Series Features:
- Flexible – Works in 12, 24, or 48V configurations
- Gives You More- You can use the complete battery’s capability, discharging it 100%
- Long-life- Even after discharging it utterly 2000 times, 80% of the capability stays.
- Maintenance Free – No watering required, or cleansing of hazardous chemical substances
- High Efficiency – Giving you up to 12% more use-able saved energy
- Smart Investment – Lower price per watt-hour/cycle and an extended lifespan than lead batteries
- Safer – No thermal run-away issues as with other lithium applied sciences
- Heavy Duty -Takes up to 150A of continuous charging/discharging current, meeting the robust calls for of great inverters and chargers
- 7.5 Year Warranty
KiloVault HLX Series Product Specifications:
1200 HLX | 1800 HLX | 3600 HLX | |
---|---|---|---|
Battery Type | Li-FePO4 | Li-FePO4 | Li-FePO4 |
Rated Capacity | 1200Wh | 1800Wh | 3600Wh |
Rated Voltage | 12.8 V DC | 12.8 V DC | 12.8 V DC |
Nominal Amp-Hour Capacity | 100Ah | 150Ah | 300Ah |
Continuous Discharge Current | 100A | 150Ah | 150Ah |
Maximum Discharge Current | 100A | 150Ah | 200A for 30 min, 150A (steady) |
Max Charge Current | 80A | 150Ah | 150Ah |
Peak Discharge Current < 3 secs | 350A | 500A | 500A |
Dimensions | |||
Length | 12.5 in (318 mm) | 19.1 in (485 mm) | 20.5 in (520 mm) |
Width | 6.5 in (165 mm) | 6.7 in (170 mm) | 8.7 in (220 mm) |
Height | 8.5 in (215 mm) | 9.4 in (240 mm) | 10.6 in (269 mm) |
Battery Weight | 27 lbs (12.2 kg) | 41.7 lbs (18.9kg) | 84.4 lbs (38.3 kg) |
Shipping Weight | 30 lbs (13.6 kg) | 45.2 lbs (20.5kg) | 103.4 lbs (46.9 kg) |
KiloVault 1800 HLX
2. KiloVault RES-Q
KiloVault RES-Q Portable Emergency Power Unit includes a 1,200 Watt-Hour battery, charge controller, and inverter that can power a refrigerator and charge cell telephones. The KiloVault RES-Q is designed to be charged by solar panels, a backup generator, or customary 120 VAC power, and will provide up to 1200Wh of emergency backup power.
KiloVault RES-Q Features:
- 1500W Pure Sinewave Inverter
- 1200Wh KiloVault Lithium Battery
- 25A Solar Charge Controller
- Built-in AC Charger
- Liquid Crystal Display Status
- 2x 120V Outlets
- 1x 12V Cigarette Lighter Adapter
- Lead Acid Battery Expansion Port
KiloVault RES-Q Specifications:
1500 RES-Q | |
---|---|
Rated Energy Capacity (Watt Hours) | 1280 Wh |
DC Voltage Nominal | 12.8V |
Nominal Amp-Hour Capacity | 100 Ah |
Cycle Rating | 2500+ cycles @ 80% Depth of Discharge |
Minimum Charge Time | 2.5 Hours |
Charge Retention | 1 Year (85%) |
Integrated Inverter | 1500W continuous output/120VAC pure sinewave/Slow begin feature protects inverter from over-current draw |
Maximum Charge Current | 15A @ 12V from AC or DC circuitry |
Maximum DC Output | 20A |
Operating Temperature | 23 – 111°F (-5 – 45°C) |
Surge Ratings | 3000W (5ms), Soft Start (for short surges) |
Environmental Rating | Indoor rated only – not rated for rainy, damp, snowy situations |
Expansion Port for External Battery | We extremely advocate using an LFP battery (ie. KiloVault). The RES-Q completely discharges the external battery, down to 10.5V, earlier than switching to the inner battery. Completely discharging a lead-acid battery will likely injury it and permanently scale back its capability. |
Warranty | 2 Year Limited |
Dimensions | |
Length | 18.9 in (480 mm) |
Width | 9.4 in (238 mm) |
Height | 15.7 in (400 mm) |
Weight | 61.7 lbs (28 kg) |
KiloVault RESQ 1500
KiloVault HLX Tips And FAQ
Is it good to insulate the KiloVault battery?
It’s the identical with any sort of battery. Because batteries warmth up when they charge, should you insulate the field they’re in, it would retain the warmth higher and the batteries will keep hotter. But make certain to take away the insulation in the scorching months, as overheated batteries can have a shorter life.
What is the most effective working and storage temperature for the KiloVault?
The optimum temperature range overall is 59 – 95°F (15 – 35°C). Full operating temperatures must be larger than 32°F (O°C) and less than 133°F (45°C). Charging the battery below 32°F (0°C) will doubtlessly damage it.
What are the really useful charge controller/inverter settings?
We highly recommend setting the Bulk/Absorb voltage to *14.0V* for a 12V system (*28.0V* for 24V system, *56.0V* for 48V), float voltage of 13.8V (27.6V for 24V, 55.2V for 48V). Higher settings will cut back the *life* of the batteries. For the inverter low voltage cut-off we strongly advocate 12.0V *or increased* (24.0V, for 24V programs, 48.0V for 48V methods). Limit the period of the absorb voltage period to 2 minutes if the charger is more than 100A, otherwise set to five minutes.
Are there any considerations when wiring the batteries in parallel?
Yes – for the HLX collection batteries, the utmost configuration is 4 parallel strings of 4 collection batteries (16). In addition, when adding another parallel row of batteries to an existing one, it is important to preserve all parallel collection strings within 0.2V of each other. Before adding a brand new row of batteries to an current one, charge all batteries to 100% first.
For the CHLX collection batteries, a most of 4 batteries can be used in collection or parallel, but NOT both. The CHLX are programmed in order that when they are in parallel or series if one gets chilly enough to start out heating, all of the CHLX in collection or parallel will begin heating. This is to forestall broadly completely different energy draws and states of charge within the battery bank when some are heating and can’t charge, while others are heat enough to charge. As the communication between the CHLX occurs by way of the power cables, if related this manner, this communication cannot happen.
Can I combine and match models or brands?
No – this is not good practice with any battery bank.
Should I do an equalization charge on the batteries?
No- very similar to AGM batteries, an equalization charge could harm them by overcharging them.
Are the batteries shipped absolutely charged, or do I have to charge them?
No – shipping pointers don’t enable deep cycle batteries to be absolutely charged during shipment. **Before you place the batteries into operation they have to ALL be charged to precisely the identical voltage (choose a voltage between 14.0-14.4, V however ensure that they’re *ALL* the same). This will ensure you start with an excellent charge throughout the battery financial institution. Suggested battery charger (cables not included with this charger however are available – use merchandise code ALTCC-6AWG-60RB). We do NOT counsel utilizing the Iota IQ-LIFE PO Smart Charger accent for use with KiloVault batteries as a result of the charge voltage is just too high.
Can I do a relentless trickle charge on the batteries?
Storing the batteries with a relentless small trickle charge just isn’t advisable. Unlike lead-acid batteries, lithium iron phosphate batteries self-consume vitality at such a low fee (0.020 amps or about 6 Watt-hours/day), the battery can be easily over-charged if put on a trickle charger. Over-charging the battery triggers the over-charge safety – shutting it down till the voltage goes down sufficient by itself. Once that happens the trickle charger would shortly raise the voltage up too high as soon as once more. As a result, the constant cycling of this circuitry will shorten the lifetime of the whole battery.
Is it unhealthy to overcharge or over-discharge the battery?
Yes, this can lower the life of the battery. It’s beneficial to never discharge or charge the battery to the purpose the place it has to shut down to guard itself.
View Complete KiloVault Product And Discount Price
Customer Reviews
Kilo Volt Amps – I have been working my new system with the KiloVault 3600 HLX for 2 weeks and it really works fantastic. I’ve watched it put out 168 amps with no issue and solely a pair tenths drop in voltage whereas doing it after which immediately returns to the conventional 13. 3 volts.
I’ve seen it charge very quickly at 68 amps from my photovoltaic array. The only challenge I’ve had is that the BMS will put this battery on standby when my PV enter matches the load on the battery… the whole system “pauses” inflicting the inverter to close off, the charge controller goes to rest, or to alarm and the 12-volt system goes useless for a couple of seconds… Be suggested the battery can go on standby…