Kilovault Battery 1800 – KiloVault® is devoted to providing innovative and affordable renewable energy solutions for residential and industrial applications.
KiloVault® design, market, and promote vitality storage and energy conversion merchandise based mostly on leading-edge applied sciences, that cut back the cost of entry for householders, and assist reduce the impact of humanity on the environment.
Kilovault Battery 1800
KiloVault® has greater than 20 years of expertise designing renewable energy programs. Our founders and lead improvement engineers have unique insight into the needs of the residential energy. This is just their newest thought to help customers retailer the solar, and save the planet.
Product Overview
Kilovault Battery 1800 – KiloVault® Solar Energy Storage merchandise cowl a variety of applications, including Flexible Energy Storage, Wall-Mount Energy Storage, and Portable Emergency Power.
1. KiloVault HLX Series
KiloVault HLX-Series Deep- Cycle Lithium Batteries supply a configurable method to residential power storage wants. The HLX Series can be used individually or together for 12, 24, or 48-volt methods, with storage capacities ranging from 150 Amp-hours to 1,200 Amp-hours.
KiloVault HLX Series Features:
- Flexible – Works in 12, 24, or 48V configurations
- Gives You More- You can use the total battery’s capacity, discharging it 100%
- Long-life- Even after discharging it fully 2000 instances, 80% of the capability remains.
- Maintenance Free – No watering required, or cleaning of hazardous chemical compounds
- High Efficiency – Giving you up to 12% more use-able saved power
- Smart Investment – Lower cost per watt-hour/cycle and a longer lifespan than lead batteries
- Safer – No thermal run-away points as with different lithium applied sciences
- Heavy Duty -Takes up to 150A of steady charging/discharging current, meeting the robust demands of serious inverters and chargers
- 7.5 Year Warranty
KiloVault HLX Series Product Specifications:
1200 HLX | 1800 HLX | 3600 HLX | |
---|---|---|---|
Battery Type | Li-FePO4 | Li-FePO4 | Li-FePO4 |
Rated Capacity | 1200Wh | 1800Wh | 3600Wh |
Rated Voltage | 12.8 V DC | 12.8 V DC | 12.8 V DC |
Nominal Amp-Hour Capacity | 100Ah | 150Ah | 300Ah |
Continuous Discharge Current | 100A | 150Ah | 150Ah |
Maximum Discharge Current | 100A | 150Ah | 200A for 30 min, 150A (steady) |
Max Charge Current | 80A | 150Ah | 150Ah |
Peak Discharge Current < 3 secs | 350A | 500A | 500A |
Dimensions | |||
Length | 12.5 in (318 mm) | 19.1 in (485 mm) | 20.5 in (520 mm) |
Width | 6.5 in (165 mm) | 6.7 in (170 mm) | 8.7 in (220 mm) |
Height | 8.5 in (215 mm) | 9.4 in (240 mm) | 10.6 in (269 mm) |
Battery Weight | 27 lbs (12.2 kg) | 41.7 lbs (18.9kg) | 84.4 lbs (38.3 kg) |
Shipping Weight | 30 lbs (13.6 kg) | 45.2 lbs (20.5kg) | 103.4 lbs (46.9 kg) |
KiloVault 1800 HLX
2. KiloVault RES-Q
KiloVault RES-Q Portable Emergency Power Unit features a 1,200 Watt-Hour battery, charge controller, and inverter that can energy a fridge and charge cell telephones. The KiloVault RES-Q is designed to be charged by solar panels, a backup generator, or customary 120 VAC power, and will present up to 1200Wh of emergency backup energy.
KiloVault RES-Q Features:
- 1500W Pure Sinewave Inverter
- 1200Wh KiloVault Lithium Battery
- 25A Solar Charge Controller
- Built-in AC Charger
- Liquid Crystal Display Status
- 2x 120V Outlets
- 1x 12V Cigarette Lighter Adapter
- Lead Acid Battery Expansion Port
KiloVault RES-Q Specifications:
1500 RES-Q | |
---|---|
Rated Energy Capacity (Watt Hours) | 1280 Wh |
DC Voltage Nominal | 12.8V |
Nominal Amp-Hour Capacity | 100 Ah |
Cycle Rating | 2500+ cycles @ 80% Depth of Discharge |
Minimum Charge Time | 2.5 Hours |
Charge Retention | 1 Year (85%) |
Integrated Inverter | 1500W steady output/120VAC pure sinewave/Slow start function protects inverter from over-current draw |
Maximum Charge Current | 15A @ 12V from AC or DC circuitry |
Maximum DC Output | 20A |
Operating Temperature | 23 – 111°F (-5 – 45°C) |
Surge Ratings | 3000W (5ms), Soft Start (for short surges) |
Environmental Rating | Indoor rated only – not rated for rainy, damp, snowy conditions |
Expansion Port for External Battery | We highly suggest utilizing an LFP battery (ie. KiloVault). The RES-Q fully discharges the exterior battery, right down to 10.5V, earlier than switching to the internal battery. Completely discharging a lead-acid battery will seemingly damage it and permanently scale back its capability. |
Warranty | 2 Year Limited |
Dimensions | |
Length | 18.9 in (480 mm) |
Width | 9.4 in (238 mm) |
Height | 15.7 in (400 mm) |
Weight | 61.7 lbs (28 kg) |
KiloVault RESQ 1500
KiloVault HLX Tips And FAQ
Is it good to insulate the KiloVault battery?
It’s the same with any sort of battery. Because batteries warmth up when they charge, if you happen to insulate the field they are in, it’s going to retain the warmth better and the batteries will stay hotter. But be certain that to remove the insulation within the hot months, as overheated batteries can have a shorter life.
What is the very best operating and storage temperature for the KiloVault?
The optimal temperature vary general is 59 – 95°F (15 – 35°C). Full working temperatures must be better than 32°F (O°C) and fewer than 133°F (45°C). Charging the battery under 32°F (0°C) will doubtlessly injury it.
What are the beneficial charge controller/inverter settings?
We highly advocate setting the Bulk/Absorb voltage to *14.0V* for a 12V system (*28.0V* for 24V system, *56.0V* for 48V), float voltage of 13.8V (27.6V for 24V, 55.2V for 48V). Higher settings will scale back the *life* of the batteries. For the inverter low voltage cut-off we strongly recommend 12.0V *or larger* (24.0V, for 24V systems, 48.0V for 48V systems). Limit the period of the take in voltage interval to 2 minutes if the charger is greater than 100A, otherwise set to 5 minutes.
Are there any considerations when wiring the batteries in parallel?
Yes – for the HLX collection batteries, the utmost configuration is 4 parallel strings of 4 series batteries (16). In addition, when adding another parallel row of batteries to an existing one, it is important to keep all parallel collection strings inside 0.2V of each other. Before adding a brand new row of batteries to an existing one, charge all batteries to 100% first.
For the CHLX collection batteries, a most of 4 batteries can be used in sequence or parallel, but NOT each. The CHLX are programmed so that when they’re in parallel or series if one gets chilly enough to start out heating, all of the CHLX in sequence or parallel will begin heating. This is to forestall widely different energy attracts and states of charge in the battery financial institution when some are heating and can’t charge, whereas others are heat sufficient to charge. As the communication between the CHLX happens through the ability cables, if related this manner, this communication cannot happen.
Can I combine and match models or brands?
No – this isn’t good follow with any battery financial institution.
Should I do an equalization charge on the batteries?
No- very like AGM batteries, an equalization charge could damage them by overcharging them.
Are the batteries shipped fully charged, or do I need to charge them?
No – shipping guidelines don’t allow deep cycle batteries to be fully charged throughout cargo. **Before you put the batteries into operation they must ALL be charged to exactly the identical voltage (select a voltage between 14.0-14.4, V but make sure they’re *ALL* the same). This will ensure you start with a good charge throughout the battery bank. Suggested battery charger (cables not included with this charger however are available – use merchandise code ALTCC-6AWG-60RB). We do NOT suggest using the Iota IQ-LIFE PO Smart Charger accessory for use with KiloVault batteries as a result of the charge voltage is too high.
Can I do a continuing trickle charge on the batteries?
Storing the batteries with a continuing small trickle charge just isn’t beneficial. Unlike lead-acid batteries, lithium iron phosphate batteries self-consume power at such a low price (0.020 amps or about 6 Watt-hours/day), the battery could be simply over-charged if put on a trickle charger. Over-charging the battery triggers the over-charge protection – shutting it down until the voltage goes down enough by itself. Once that occurs the trickle charger would rapidly elevate the voltage up too excessive once once more. As a result, the constant biking of this circuitry will shorten the life of your entire battery.
Is it bad to overcharge or over-discharge the battery?
Yes, this can lower the life of the battery. It’s really useful to by no means discharge or charge the battery to the point the place it has to close down to guard itself.
View Complete KiloVault Product And Discount Price
Customer Reviews
Kilovault Battery 1800 – I’ve been working my new system with the KiloVault 3600 HLX for 2 weeks and it really works incredible. I’ve watched it put out 168 amps with no subject and solely a couple tenths drop in voltage whereas doing it after which instantly returns to the conventional 13. 3 volts.
I have seen it charge in a short time at 68 amps from my solar array. The only difficulty I have had is that the BMS will put this battery on standby when my PV input matches the load on the battery… your entire system “pauses” inflicting the inverter to close off, the charge controller goes to relaxation, or to alarm and the 12-volt system goes lifeless for a couple of seconds… Be advised the battery can go on standby…