Kilovault Battery Balancer – KiloVault® is dedicated to offering modern and affordable renewable energy options for residential and industrial functions.
KiloVault® design, market, and sell energy storage and power conversion products based mostly on modern technologies, that scale back the cost of entry for owners, and help cut back the affect of humanity on the atmosphere.
Kilovault Battery Balancer
KiloVault® has greater than 20 years of expertise designing renewable energy programs. Our founders and lead improvement engineers have unique insight into the needs of the residential power. This is just their newest thought to help customers retailer the sun, and save the planet.
Product Overview
Kilovault Battery Balancer – KiloVault® Solar Energy Storage products cowl a wide range of applications, including Flexible Energy Storage, Wall-Mount Energy Storage, and Portable Emergency Power.
1. KiloVault HLX Series
KiloVault HLX-Series Deep- Cycle Lithium Batteries provide a configurable method to residential power storage wants. The HLX Series can be used individually or in combination for 12, 24, or 48-volt methods, with storage capacities starting from 150 Amp-hours to 1,200 Amp-hours.
KiloVault HLX Series Features:
- Flexible – Works in 12, 24, or 48V configurations
- Gives You More- You can use the total battery’s capability, discharging it 100%
- Long-life- Even after discharging it utterly 2000 times, 80% of the capacity stays.
- Maintenance Free – No watering required, or cleansing of hazardous chemical compounds
- High Efficiency – Giving you up to 12% more use-able stored energy
- Smart Investment – Lower cost per watt-hour/cycle and an extended lifespan than lead batteries
- Safer – No thermal run-away points as with other lithium applied sciences
- Heavy Duty -Takes up to 150A of continuous charging/discharging present, assembly the tough calls for of serious inverters and chargers
- 7.5 Year Warranty
KiloVault HLX Series Product Specifications:
1200 HLX | 1800 HLX | 3600 HLX | |
---|---|---|---|
Battery Type | Li-FePO4 | Li-FePO4 | Li-FePO4 |
Rated Capacity | 1200Wh | 1800Wh | 3600Wh |
Rated Voltage | 12.8 V DC | 12.8 V DC | 12.8 V DC |
Nominal Amp-Hour Capacity | 100Ah | 150Ah | 300Ah |
Continuous Discharge Current | 100A | 150Ah | 150Ah |
Maximum Discharge Current | 100A | 150Ah | 200A for 30 min, 150A (continuous) |
Max Charge Current | 80A | 150Ah | 150Ah |
Peak Discharge Current < 3 secs | 350A | 500A | 500A |
Dimensions | |||
Length | 12.5 in (318 mm) | 19.1 in (485 mm) | 20.5 in (520 mm) |
Width | 6.5 in (165 mm) | 6.7 in (170 mm) | 8.7 in (220 mm) |
Height | 8.5 in (215 mm) | 9.4 in (240 mm) | 10.6 in (269 mm) |
Battery Weight | 27 lbs (12.2 kg) | 41.7 lbs (18.9kg) | 84.4 lbs (38.3 kg) |
Shipping Weight | 30 lbs (13.6 kg) | 45.2 lbs (20.5kg) | 103.4 lbs (46.9 kg) |
KiloVault 1800 HLX
2. KiloVault RES-Q
KiloVault RES-Q Portable Emergency Power Unit features a 1,200 Watt-Hour battery, charge controller, and inverter that can energy a fridge and charge cell telephones. The KiloVault RES-Q is designed to be charged by photovoltaic panels, a backup generator, or customary 120 VAC power, and can provide as much as 1200Wh of emergency backup energy.
KiloVault RES-Q Features:
- 1500W Pure Sinewave Inverter
- 1200Wh KiloVault Lithium Battery
- 25A Solar Charge Controller
- Built-in AC Charger
- Liquid Crystal Display Status
- 2x 120V Outlets
- 1x 12V Cigarette Lighter Adapter
- Lead Acid Battery Expansion Port
KiloVault RES-Q Specifications:
1500 RES-Q | |
---|---|
Rated Energy Capacity (Watt Hours) | 1280 Wh |
DC Voltage Nominal | 12.8V |
Nominal Amp-Hour Capacity | 100 Ah |
Cycle Rating | 2500+ cycles @ 80% Depth of Discharge |
Minimum Charge Time | 2.5 Hours |
Charge Retention | 1 Year (85%) |
Integrated Inverter | 1500W continuous output/120VAC pure sinewave/Slow begin feature protects inverter from over-current draw |
Maximum Charge Current | 15A @ 12V from AC or DC circuitry |
Maximum DC Output | 20A |
Operating Temperature | 23 – 111°F (-5 – 45°C) |
Surge Ratings | 3000W (5ms), Soft Start (for brief surges) |
Environmental Rating | Indoor rated solely – not rated for rainy, damp, snowy conditions |
Expansion Port for External Battery | We extremely advocate utilizing an LFP battery (ie. KiloVault). The RES-Q completely discharges the external battery, down to 10.5V, before switching to the interior battery. Completely discharging a lead-acid battery will likely injury it and completely cut back its capability. |
Warranty | 2 Year Limited |
Dimensions | |
Length | 18.9 in (480 mm) |
Width | 9.4 in (238 mm) |
Height | 15.7 in (400 mm) |
Weight | 61.7 lbs (28 kg) |
KiloVault RESQ 1500
KiloVault HLX Tips And FAQ
Is it good to insulate the KiloVault battery?
It’s the same with any type of battery. Because batteries heat up once they charge, when you insulate the field they are in, it can retain the heat higher and the batteries will stay hotter. But make sure to remove the insulation within the scorching months, as overheated batteries could have a shorter life.
What is the perfect operating and storage temperature for the KiloVault?
The optimum temperature range general is 59 – 95°F (15 – 35°C). Full working temperatures should be greater than 32°F (O°C) and less than 133°F (45°C). Charging the battery under 32°F (0°C) will potentially harm it.
What are the really helpful charge controller/inverter settings?
We extremely recommend setting the Bulk/Absorb voltage to *14.0V* for a 12V system (*28.0V* for 24V system, *56.0V* for 48V), float voltage of 13.8V (27.6V for 24V, 55.2V for 48V). Higher settings will cut back the *life* of the batteries. For the inverter low voltage cut-off we strongly recommend 12.0V *or higher* (24.0V, for 24V programs, 48.0V for 48V programs). Limit the period of the absorb voltage interval to 2 minutes if the charger is more than 100A, otherwise set to 5 minutes.
Are there any considerations when wiring the batteries in parallel?
Yes – for the HLX collection batteries, the utmost configuration is 4 parallel strings of 4 series batteries (16). In addition, when including another parallel row of batteries to an current one, it is very important keep all parallel sequence strings inside 0.2V of one another. Before adding a brand new row of batteries to an present one, charge all batteries to 100% first.
For the CHLX collection batteries, a most of 4 batteries can be utilized in series or parallel, however NOT both. The CHLX are programmed in order that when they’re in parallel or collection if one will get cold enough to begin heating, the entire CHLX in series or parallel will start heating. This is to stop extensively completely different energy attracts and states of charge within the battery bank when some are heating and cannot charge, while others are heat enough to charge. As the communication between the CHLX occurs through the ability cables, if related this manner, this communication cannot happen.
Can I combine and match models or manufacturers?
No – this isn’t good observe with any battery financial institution.
Should I do an equalization charge on the batteries?
No- very like AGM batteries, an equalization charge might injury them by overcharging them.
Are the batteries shipped fully charged, or do I have to charge them?
No – shipping tips don’t permit deep cycle batteries to be fully charged throughout cargo. **Before you place the batteries into operation they must ALL be charged to precisely the same voltage (select a voltage between 14.0-14.4, V however be sure that they are *ALL* the identical). This will ensure you start with an excellent charge throughout the battery bank. Suggested battery charger (cables not included with this charger however are available – use item code ALTCC-6AWG-60RB). We do NOT suggest using the Iota IQ-LIFE PO Smart Charger accent to be used with KiloVault batteries as a result of the charge voltage is simply too high.
Can I do a constant trickle charge on the batteries?
Storing the batteries with a continuing small trickle charge is not really helpful. Unlike lead-acid batteries, lithium iron phosphate batteries self-consume power at such a low fee (0.020 amps or about 6 Watt-hours/day), the battery may be simply over-charged if placed on a trickle charger. Over-charging the battery triggers the over-charge safety – shutting it down till the voltage goes down enough by itself. Once that occurs the trickle charger would quickly elevate the voltage up too excessive as soon as once more. As a outcome, the constant biking of this circuitry will shorten the life of the whole battery.
Is it dangerous to overcharge or over-discharge the battery?
Yes, this may decrease the lifetime of the battery. It’s beneficial to never discharge or charge the battery to the point where it has to close down to guard itself.
View Complete KiloVault Product And Discount Price
Customer Reviews
Kilovault Battery Balancer – I’ve been running my new system with the KiloVault 3600 HLX for 2 weeks and it works unbelievable. I’ve watched it put out 168 amps with no challenge and only a couple tenths drop in voltage while doing it after which immediately returns to the traditional 13. 3 volts.
I have seen it charge in a short time at 68 amps from my photovoltaic array. The solely problem I have had is that the BMS will put this battery on standby when my PV enter matches the load on the battery… the entire system “pauses” inflicting the inverter to shut off, the charge controller goes to rest, or to alarm and the 12-volt system goes dead for a few seconds… Be suggested the battery can go on standby…
View More KiloVault Helpful Reviews