Kilovault Battery Balancer – KiloVault® is devoted to providing innovative and affordable renewable power options for residential and business functions.
KiloVault® design, market, and promote vitality storage and power conversion merchandise primarily based on leading-edge applied sciences, that scale back the price of entry for homeowners, and help scale back the affect of humanity on the atmosphere.
Kilovault Battery Balancer
KiloVault® has more than 20 years of experience designing renewable energy techniques. Our founders and lead growth engineers have unique perception into the needs of the residential energy. This is just their newest concept to help customers retailer the solar, and save the planet.
Product Overview
Kilovault Battery Balancer – KiloVault® Solar Energy Storage merchandise cover a wide range of functions, including Flexible Energy Storage, Wall-Mount Energy Storage, and Portable Emergency Power.
1. KiloVault HLX Series
KiloVault HLX-Series Deep- Cycle Lithium Batteries offer a configurable method to residential power storage needs. The HLX Series can be utilized individually or together for 12, 24, or 48-volt techniques, with storage capacities ranging from 150 Amp-hours to 1,200 Amp-hours.
KiloVault HLX Series Features:
- Flexible – Works in 12, 24, or 48V configurations
- Gives You More- You can use the complete battery’s capability, discharging it 100%
- Long-life- Even after discharging it fully 2000 times, 80% of the capability remains.
- Maintenance Free – No watering required, or cleaning of hazardous chemical compounds
- High Efficiency – Giving you as much as 12% extra use-able saved vitality
- Smart Investment – Lower price per watt-hour/cycle and a longer lifespan than lead batteries
- Safer – No thermal run-away issues as with different lithium applied sciences
- Heavy Duty -Takes up to 150A of continuous charging/discharging present, meeting the tough demands of serious inverters and chargers
- 7.5 Year Warranty
KiloVault HLX Series Product Specifications:
1200 HLX | 1800 HLX | 3600 HLX | |
---|---|---|---|
Battery Type | Li-FePO4 | Li-FePO4 | Li-FePO4 |
Rated Capacity | 1200Wh | 1800Wh | 3600Wh |
Rated Voltage | 12.8 V DC | 12.8 V DC | 12.8 V DC |
Nominal Amp-Hour Capacity | 100Ah | 150Ah | 300Ah |
Continuous Discharge Current | 100A | 150Ah | 150Ah |
Maximum Discharge Current | 100A | 150Ah | 200A for 30 min, 150A (continuous) |
Max Charge Current | 80A | 150Ah | 150Ah |
Peak Discharge Current < 3 secs | 350A | 500A | 500A |
Dimensions | |||
Length | 12.5 in (318 mm) | 19.1 in (485 mm) | 20.5 in (520 mm) |
Width | 6.5 in (165 mm) | 6.7 in (170 mm) | 8.7 in (220 mm) |
Height | 8.5 in (215 mm) | 9.4 in (240 mm) | 10.6 in (269 mm) |
Battery Weight | 27 lbs (12.2 kg) | 41.7 lbs (18.9kg) | 84.4 lbs (38.3 kg) |
Shipping Weight | 30 lbs (13.6 kg) | 45.2 lbs (20.5kg) | 103.4 lbs (46.9 kg) |
KiloVault 1800 HLX
2. KiloVault RES-Q
KiloVault RES-Q Portable Emergency Power Unit features a 1,200 Watt-Hour battery, charge controller, and inverter that can power a refrigerator and charge cell telephones. The KiloVault RES-Q is designed to be charged by solar panels, a backup generator, or normal 120 VAC power, and can provide as much as 1200Wh of emergency backup power.
KiloVault RES-Q Features:
- 1500W Pure Sinewave Inverter
- 1200Wh KiloVault Lithium Battery
- 25A Solar Charge Controller
- Built-in AC Charger
- Liquid Crystal Display Status
- 2x 120V Outlets
- 1x 12V Cigarette Lighter Adapter
- Lead Acid Battery Expansion Port
KiloVault RES-Q Specifications:
1500 RES-Q | |
---|---|
Rated Energy Capacity (Watt Hours) | 1280 Wh |
DC Voltage Nominal | 12.8V |
Nominal Amp-Hour Capacity | 100 Ah |
Cycle Rating | 2500+ cycles @ 80% Depth of Discharge |
Minimum Charge Time | 2.5 Hours |
Charge Retention | 1 Year (85%) |
Integrated Inverter | 1500W steady output/120VAC pure sinewave/Slow start function protects inverter from over-current draw |
Maximum Charge Current | 15A @ 12V from AC or DC circuitry |
Maximum DC Output | 20A |
Operating Temperature | 23 – 111°F (-5 – 45°C) |
Surge Ratings | 3000W (5ms), Soft Start (for short surges) |
Environmental Rating | Indoor rated solely – not rated for wet, damp, snowy circumstances |
Expansion Port for External Battery | We highly advocate using an LFP battery (ie. KiloVault). The RES-Q fully discharges the exterior battery, right down to 10.5V, before switching to the internal battery. Completely discharging a lead-acid battery will probably harm it and permanently cut back its capacity. |
Warranty | 2 Year Limited |
Dimensions | |
Length | 18.9 in (480 mm) |
Width | 9.4 in (238 mm) |
Height | 15.7 in (400 mm) |
Weight | 61.7 lbs (28 kg) |
KiloVault RESQ 1500
KiloVault HLX Tips And FAQ
Is it good to insulate the KiloVault battery?
It’s the identical with any kind of battery. Because batteries heat up when they charge, for those who insulate the field they are in, it should retain the heat higher and the batteries will stay hotter. But make sure that to take away the insulation in the sizzling months, as overheated batteries may have a shorter life.
What is one of the best working and storage temperature for the KiloVault?
The optimum temperature vary general is 59 – 95°F (15 – 35°C). Full working temperatures have to be larger than 32°F (O°C) and less than 133°F (45°C). Charging the battery beneath 32°F (0°C) will doubtlessly harm it.
What are the beneficial charge controller/inverter settings?
We highly suggest setting the Bulk/Absorb voltage to *14.0V* for a 12V system (*28.0V* for 24V system, *56.0V* for 48V), float voltage of 13.8V (27.6V for 24V, 55.2V for 48V). Higher settings will scale back the *life* of the batteries. For the inverter low voltage cut-off we strongly recommend 12.0V *or higher* (24.0V, for 24V techniques, 48.0V for 48V techniques). Limit the duration of the take in voltage period to 2 minutes if the charger is greater than 100A, in any other case set to five minutes.
Are there any concerns when wiring the batteries in parallel?
Yes – for the HLX sequence batteries, the maximum configuration is 4 parallel strings of 4 collection batteries (16). In addition, when adding another parallel row of batteries to an existing one, it is important to keep all parallel series strings within 0.2V of each other. Before adding a new row of batteries to an current one, charge all batteries to 100% first.
For the CHLX collection batteries, a most of 4 batteries can be used in collection or parallel, but NOT each. The CHLX are programmed so that when they’re in parallel or sequence if one gets cold sufficient to start out heating, all of the CHLX in series or parallel will begin heating. This is to stop extensively different energy attracts and states of charge within the battery financial institution when some are heating and can’t charge, while others are heat enough to charge. As the communication between the CHLX happens by way of the ability cables, if linked this manner, this communication can not happen.
Can I combine and match models or brands?
No – this is not good follow with any battery financial institution.
Should I do an equalization charge on the batteries?
No- very similar to AGM batteries, an equalization charge might harm them by overcharging them.
Are the batteries shipped totally charged, or do I must charge them?
No – transport tips do not enable deep cycle batteries to be absolutely charged throughout cargo. **Before you put the batteries into operation they must ALL be charged to exactly the identical voltage (choose a voltage between 14.0-14.4, V however make certain they’re *ALL* the same). This will ensure you start with a fair charge across the battery bank. Suggested battery charger (cables not included with this charger but are available – use merchandise code ALTCC-6AWG-60RB). We do NOT suggest using the Iota IQ-LIFE PO Smart Charger accent to be used with KiloVault batteries as a result of the charge voltage is just too high.
Can I do a continuing trickle charge on the batteries?
Storing the batteries with a relentless small trickle charge will not be really helpful. Unlike lead-acid batteries, lithium iron phosphate batteries self-consume energy at such a low rate (0.020 amps or about 6 Watt-hours/day), the battery will be easily over-charged if put on a trickle charger. Over-charging the battery triggers the over-charge safety – shutting it down till the voltage goes down sufficient by itself. Once that occurs the trickle charger would rapidly increase the voltage up too high as soon as again. As a outcome, the fixed cycling of this circuitry will shorten the life of all the battery.
Is it bad to overcharge or over-discharge the battery?
Yes, this will decrease the life of the battery. It’s advisable to never discharge or charge the battery to the purpose where it has to shut down to guard itself.
View Complete KiloVault Product And Discount Price
Customer Reviews
Kilovault Battery Balancer – I’ve been working my new system with the KiloVault 3600 HLX for 2 weeks and it really works unbelievable. I’ve watched it put out 168 amps with no challenge and only a pair tenths drop in voltage while doing it and then instantly returns to the conventional 13. 3 volts.
I have seen it charge in a short time at 68 amps from my solar array. The only subject I’ve had is that the BMS will put this battery on standby when my PV enter matches the load on the battery… your complete system “pauses” inflicting the inverter to shut off, the charge controller goes to relaxation, or to alarm and the 12-volt system goes useless for a few seconds… Be suggested the battery can go on standby…
View More KiloVault Helpful Reviews