Kilovault Vs Battleborn – KiloVault® is dedicated to offering innovative and affordable renewable energy solutions for residential and industrial functions.
KiloVault® design, market, and promote vitality storage and energy conversion products primarily based on modern technologies, that cut back the price of entry for owners, and help cut back the affect of humanity on the surroundings.
Kilovault Vs Battleborn
KiloVault® has greater than 20 years of experience designing renewable power programs. Our founders and lead development engineers have distinctive insight into the needs of the residential energy. This is just their newest concept to help customers retailer the sun, and save the planet.
Product Overview
Kilovault Vs Battleborn – KiloVault® Solar Energy Storage products cowl a wide range of functions, together with Flexible Energy Storage, Wall-Mount Energy Storage, and Portable Emergency Power.
1. KiloVault HLX Series
KiloVault HLX-Series Deep- Cycle Lithium Batteries supply a configurable strategy to residential vitality storage needs. The HLX Series can be used individually or in combination for 12, 24, or 48-volt programs, with storage capacities starting from 150 Amp-hours to 1,200 Amp-hours.
KiloVault HLX Series Features:
- Flexible – Works in 12, 24, or 48V configurations
- Gives You More- You can use the total battery’s capability, discharging it 100%
- Long-life- Even after discharging it fully 2000 times, 80% of the capability stays.
- Maintenance Free – No watering required, or cleansing of hazardous chemicals
- High Efficiency – Giving you up to 12% extra use-able stored energy
- Smart Investment – Lower price per watt-hour/cycle and an extended lifespan than lead batteries
- Safer – No thermal run-away issues as with different lithium applied sciences
- Heavy Duty -Takes as much as 150A of continuous charging/discharging current, assembly the robust calls for of significant inverters and chargers
- 7.5 Year Warranty
KiloVault HLX Series Product Specifications:
1200 HLX | 1800 HLX | 3600 HLX | |
---|---|---|---|
Battery Type | Li-FePO4 | Li-FePO4 | Li-FePO4 |
Rated Capacity | 1200Wh | 1800Wh | 3600Wh |
Rated Voltage | 12.8 V DC | 12.8 V DC | 12.8 V DC |
Nominal Amp-Hour Capacity | 100Ah | 150Ah | 300Ah |
Continuous Discharge Current | 100A | 150Ah | 150Ah |
Maximum Discharge Current | 100A | 150Ah | 200A for 30 min, 150A (steady) |
Max Charge Current | 80A | 150Ah | 150Ah |
Peak Discharge Current < 3 secs | 350A | 500A | 500A |
Dimensions | |||
Length | 12.5 in (318 mm) | 19.1 in (485 mm) | 20.5 in (520 mm) |
Width | 6.5 in (165 mm) | 6.7 in (170 mm) | 8.7 in (220 mm) |
Height | 8.5 in (215 mm) | 9.4 in (240 mm) | 10.6 in (269 mm) |
Battery Weight | 27 lbs (12.2 kg) | 41.7 lbs (18.9kg) | 84.4 lbs (38.3 kg) |
Shipping Weight | 30 lbs (13.6 kg) | 45.2 lbs (20.5kg) | 103.4 lbs (46.9 kg) |
KiloVault 1800 HLX
2. KiloVault RES-Q
KiloVault RES-Q Portable Emergency Power Unit includes a 1,200 Watt-Hour battery, charge controller, and inverter that may energy a refrigerator and charge cell telephones. The KiloVault RES-Q is designed to be charged by solar panels, a backup generator, or commonplace 120 VAC energy, and will provide as much as 1200Wh of emergency backup energy.
KiloVault RES-Q Features:
- 1500W Pure Sinewave Inverter
- 1200Wh KiloVault Lithium Battery
- 25A Solar Charge Controller
- Built-in AC Charger
- Liquid Crystal Display Status
- 2x 120V Outlets
- 1x 12V Cigarette Lighter Adapter
- Lead Acid Battery Expansion Port
KiloVault RES-Q Specifications:
1500 RES-Q | |
---|---|
Rated Energy Capacity (Watt Hours) | 1280 Wh |
DC Voltage Nominal | 12.8V |
Nominal Amp-Hour Capacity | 100 Ah |
Cycle Rating | 2500+ cycles @ 80% Depth of Discharge |
Minimum Charge Time | 2.5 Hours |
Charge Retention | 1 Year (85%) |
Integrated Inverter | 1500W steady output/120VAC pure sinewave/Slow start characteristic protects inverter from over-current draw |
Maximum Charge Current | 15A @ 12V from AC or DC circuitry |
Maximum DC Output | 20A |
Operating Temperature | 23 – 111°F (-5 – 45°C) |
Surge Ratings | 3000W (5ms), Soft Start (for brief surges) |
Environmental Rating | Indoor rated only – not rated for wet, damp, snowy situations |
Expansion Port for External Battery | We extremely advocate using an LFP battery (ie. KiloVault). The RES-Q completely discharges the external battery, all the way down to 10.5V, before switching to the internal battery. Completely discharging a lead-acid battery will seemingly harm it and completely scale back its capacity. |
Warranty | 2 Year Limited |
Dimensions | |
Length | 18.9 in (480 mm) |
Width | 9.4 in (238 mm) |
Height | 15.7 in (400 mm) |
Weight | 61.7 lbs (28 kg) |
KiloVault RESQ 1500
KiloVault HLX Tips And FAQ
Is it good to insulate the KiloVault battery?
It’s the same with any type of battery. Because batteries warmth up after they charge, when you insulate the box they are in, it’s going to retain the warmth higher and the batteries will stay hotter. But make certain to remove the insulation within the hot months, as overheated batteries will have a shorter life.
What is one of the best working and storage temperature for the KiloVault?
The optimal temperature range total is 59 – 95°F (15 – 35°C). Full operating temperatures should be higher than 32°F (O°C) and less than 133°F (45°C). Charging the battery under 32°F (0°C) will probably injury it.
What are the really useful charge controller/inverter settings?
We highly suggest setting the Bulk/Absorb voltage to *14.0V* for a 12V system (*28.0V* for 24V system, *56.0V* for 48V), float voltage of 13.8V (27.6V for 24V, 55.2V for 48V). Higher settings will cut back the *life* of the batteries. For the inverter low voltage cut-off we strongly recommend 12.0V *or higher* (24.0V, for 24V systems, 48.0V for 48V techniques). Limit the length of the take in voltage interval to 2 minutes if the charger is greater than 100A, in any other case set to 5 minutes.
Are there any issues when wiring the batteries in parallel?
Yes – for the HLX sequence batteries, the maximum configuration is 4 parallel strings of 4 collection batteries (16). In addition, when adding one other parallel row of batteries to an existing one, it is very important preserve all parallel sequence strings within 0.2V of each other. Before adding a new row of batteries to an present one, charge all batteries to 100% first.
For the CHLX series batteries, a most of 4 batteries can be used in sequence or parallel, however NOT each. The CHLX are programmed in order that when they are in parallel or series if one gets cold enough to start out heating, all of the CHLX in sequence or parallel will begin heating. This is to stop widely completely different power attracts and states of charge in the battery bank when some are heating and cannot charge, whereas others are heat sufficient to charge. As the communication between the CHLX occurs through the ability cables, if related this fashion, this communication can not happen.
Can I combine and match models or brands?
No – this isn’t good apply with any battery financial institution.
Should I do an equalization charge on the batteries?
No- very like AGM batteries, an equalization charge could damage them by overcharging them.
Are the batteries shipped totally charged, or do I have to charge them?
No – delivery guidelines do not allow deep cycle batteries to be absolutely charged during shipment. **Before you place the batteries into operation they must ALL be charged to exactly the identical voltage (select a voltage between 14.0-14.4, V but be certain that they’re *ALL* the identical). This will make sure you begin with an excellent charge across the battery financial institution. Suggested battery charger (cables not included with this charger but are available – use merchandise code ALTCC-6AWG-60RB). We do NOT suggest utilizing the Iota IQ-LIFE PO Smart Charger accessory to be used with KiloVault batteries as a result of the charge voltage is too excessive.
Can I do a continuing trickle charge on the batteries?
Storing the batteries with a relentless small trickle charge is not advisable. Unlike lead-acid batteries, lithium iron phosphate batteries self-consume power at such a low fee (0.020 amps or about 6 Watt-hours/day), the battery will be easily over-charged if put on a trickle charger. Over-charging the battery triggers the over-charge safety – shutting it down till the voltage goes down enough by itself. Once that happens the trickle charger would quickly raise the voltage up too excessive as soon as again. As a outcome, the fixed cycling of this circuitry will shorten the life of the entire battery.
Is it dangerous to overcharge or over-discharge the battery?
Yes, this may decrease the life of the battery. It’s really helpful to by no means discharge or charge the battery to the purpose where it has to close down to guard itself.
View Complete KiloVault Product And Discount Price
Customer Reviews
Kilovault Vs Battleborn – I have been operating my new system with the KiloVault 3600 HLX for two weeks and it really works improbable. I’ve watched it put out 168 amps with no concern and solely a pair tenths drop in voltage whereas doing it and then instantly returns to the traditional 13. 3 volts.
I have seen it charge very quickly at 68 amps from my photovoltaic array. The solely issue I’ve had is that the BMS will put this battery on standby when my PV input matches the load on the battery… the complete system “pauses” causing the inverter to close off, the charge controller goes to relaxation, or to alarm and the 12-volt system goes lifeless for a couple of seconds… Be suggested the battery can go on standby…
View More KiloVault Helpful Reviews