Kilovault Battery Review – KiloVault® is dedicated to offering modern and affordable renewable vitality solutions for residential and industrial functions.
KiloVault® design, market, and sell vitality storage and power conversion merchandise primarily based on modern applied sciences, that scale back the cost of entry for homeowners, and assist cut back the affect of humanity on the atmosphere.
Kilovault Battery Review
KiloVault® has more than 20 years of expertise designing renewable vitality systems. Our founders and lead development engineers have unique perception into the wants of the residential power. This is just their newest concept to help customers retailer the sun, and save the planet.
Product Overview
Kilovault Battery Review – KiloVault® Solar Energy Storage products cover a wide range of functions, including Flexible Energy Storage, Wall-Mount Energy Storage, and Portable Emergency Power.
1. KiloVault HLX Series
KiloVault HLX-Series Deep- Cycle Lithium Batteries offer a configurable strategy to residential vitality storage wants. The HLX Series can be used individually or in combination for 12, 24, or 48-volt methods, with storage capacities starting from 150 Amp-hours to 1,200 Amp-hours.
KiloVault HLX Series Features:
- Flexible – Works in 12, 24, or 48V configurations
- Gives You More- You can use the total battery’s capability, discharging it 100%
- Long-life- Even after discharging it fully 2000 occasions, 80% of the capacity remains.
- Maintenance Free – No watering required, or cleansing of hazardous chemicals
- High Efficiency – Giving you up to 12% more use-able saved energy
- Smart Investment – Lower value per watt-hour/cycle and an extended lifespan than lead batteries
- Safer – No thermal run-away points as with different lithium technologies
- Heavy Duty -Takes up to 150A of continuous charging/discharging current, assembly the robust calls for of significant inverters and chargers
- 7.5 Year Warranty
KiloVault HLX Series Product Specifications:
1200 HLX | 1800 HLX | 3600 HLX | |
---|---|---|---|
Battery Type | Li-FePO4 | Li-FePO4 | Li-FePO4 |
Rated Capacity | 1200Wh | 1800Wh | 3600Wh |
Rated Voltage | 12.8 V DC | 12.8 V DC | 12.8 V DC |
Nominal Amp-Hour Capacity | 100Ah | 150Ah | 300Ah |
Continuous Discharge Current | 100A | 150Ah | 150Ah |
Maximum Discharge Current | 100A | 150Ah | 200A for 30 min, 150A (continuous) |
Max Charge Current | 80A | 150Ah | 150Ah |
Peak Discharge Current < 3 secs | 350A | 500A | 500A |
Dimensions | |||
Length | 12.5 in (318 mm) | 19.1 in (485 mm) | 20.5 in (520 mm) |
Width | 6.5 in (165 mm) | 6.7 in (170 mm) | 8.7 in (220 mm) |
Height | 8.5 in (215 mm) | 9.4 in (240 mm) | 10.6 in (269 mm) |
Battery Weight | 27 lbs (12.2 kg) | 41.7 lbs (18.9kg) | 84.4 lbs (38.3 kg) |
Shipping Weight | 30 lbs (13.6 kg) | 45.2 lbs (20.5kg) | 103.4 lbs (46.9 kg) |
KiloVault 1800 HLX
2. KiloVault RES-Q
KiloVault RES-Q Portable Emergency Power Unit features a 1,200 Watt-Hour battery, charge controller, and inverter that can energy a refrigerator and charge cell phones. The KiloVault RES-Q is designed to be charged by solar panels, a backup generator, or commonplace 120 VAC power, and can provide up to 1200Wh of emergency backup power.
KiloVault RES-Q Features:
- 1500W Pure Sinewave Inverter
- 1200Wh KiloVault Lithium Battery
- 25A Solar Charge Controller
- Built-in AC Charger
- Liquid Crystal Display Status
- 2x 120V Outlets
- 1x 12V Cigarette Lighter Adapter
- Lead Acid Battery Expansion Port
KiloVault RES-Q Specifications:
1500 RES-Q | |
---|---|
Rated Energy Capacity (Watt Hours) | 1280 Wh |
DC Voltage Nominal | 12.8V |
Nominal Amp-Hour Capacity | 100 Ah |
Cycle Rating | 2500+ cycles @ 80% Depth of Discharge |
Minimum Charge Time | 2.5 Hours |
Charge Retention | 1 Year (85%) |
Integrated Inverter | 1500W continuous output/120VAC pure sinewave/Slow begin function protects inverter from over-current draw |
Maximum Charge Current | 15A @ 12V from AC or DC circuitry |
Maximum DC Output | 20A |
Operating Temperature | 23 – 111°F (-5 – 45°C) |
Surge Ratings | 3000W (5ms), Soft Start (for short surges) |
Environmental Rating | Indoor rated only – not rated for rainy, damp, snowy situations |
Expansion Port for External Battery | We extremely advocate utilizing an LFP battery (ie. KiloVault). The RES-Q utterly discharges the exterior battery, right down to 10.5V, before switching to the interior battery. Completely discharging a lead-acid battery will probably damage it and permanently scale back its capacity. |
Warranty | 2 Year Limited |
Dimensions | |
Length | 18.9 in (480 mm) |
Width | 9.4 in (238 mm) |
Height | 15.7 in (400 mm) |
Weight | 61.7 lbs (28 kg) |
KiloVault RESQ 1500
KiloVault HLX Tips And FAQ
Is it good to insulate the KiloVault battery?
It’s the identical with any sort of battery. Because batteries heat up after they charge, if you happen to insulate the box they are in, it will retain the warmth higher and the batteries will keep hotter. But make certain to remove the insulation in the hot months, as overheated batteries could have a shorter life.
What is the very best operating and storage temperature for the KiloVault?
The optimum temperature range overall is 59 – 95°F (15 – 35°C). Full working temperatures have to be greater than 32°F (O°C) and fewer than 133°F (45°C). Charging the battery under 32°F (0°C) will probably injury it.
What are the advisable charge controller/inverter settings?
We extremely advocate setting the Bulk/Absorb voltage to *14.0V* for a 12V system (*28.0V* for 24V system, *56.0V* for 48V), float voltage of 13.8V (27.6V for 24V, 55.2V for 48V). Higher settings will cut back the *life* of the batteries. For the inverter low voltage cut-off we strongly recommend 12.0V *or larger* (24.0V, for 24V programs, 48.0V for 48V programs). Limit the period of the take in voltage period to 2 minutes if the charger is more than 100A, in any other case set to five minutes.
Are there any concerns when wiring the batteries in parallel?
Yes – for the HLX series batteries, the maximum configuration is 4 parallel strings of 4 sequence batteries (16). In addition, when adding one other parallel row of batteries to an current one, you will need to preserve all parallel sequence strings within 0.2V of each other. Before including a brand new row of batteries to an current one, charge all batteries to 100% first.
For the CHLX sequence batteries, a most of 4 batteries can be used in collection or parallel, however NOT each. The CHLX are programmed in order that when they’re in parallel or sequence if one will get cold sufficient to start heating, all the CHLX in sequence or parallel will start heating. This is to prevent extensively different energy draws and states of charge in the battery bank when some are heating and cannot charge, while others are heat sufficient to charge. As the communication between the CHLX occurs via the ability cables, if linked this fashion, this communication can’t happen.
Can I mix and match models or manufacturers?
No – this is not good practice with any battery bank.
Should I do an equalization charge on the batteries?
No- very similar to AGM batteries, an equalization charge might harm them by overcharging them.
Are the batteries shipped absolutely charged, or do I need to charge them?
No – delivery tips don’t allow deep cycle batteries to be totally charged throughout cargo. **Before you put the batteries into operation they must ALL be charged to precisely the identical voltage (choose a voltage between 14.0-14.4, V however be certain they’re *ALL* the identical). This will ensure you begin with a fair charge across the battery financial institution. Suggested battery charger (cables not included with this charger however are available – use item code ALTCC-6AWG-60RB). We do NOT counsel utilizing the Iota IQ-LIFE PO Smart Charger accent for use with KiloVault batteries as a result of the charge voltage is just too excessive.
Can I do a constant trickle charge on the batteries?
Storing the batteries with a continuing small trickle charge is just not beneficial. Unlike lead-acid batteries, lithium iron phosphate batteries self-consume power at such a low fee (0.020 amps or about 6 Watt-hours/day), the battery will be simply over-charged if put on a trickle charger. Over-charging the battery triggers the over-charge safety – shutting it down until the voltage goes down sufficient by itself. Once that happens the trickle charger would quickly elevate the voltage up too high as soon as once more. As a end result, the constant biking of this circuitry will shorten the life of the entire battery.
Is it dangerous to overcharge or over-discharge the battery?
Yes, this will lower the lifetime of the battery. It’s really helpful to never discharge or charge the battery to the point where it has to close down to guard itself.
View Complete KiloVault Product And Discount Price
Customer Reviews
Kilovault Battery Review – I’ve been running my new system with the KiloVault 3600 HLX for two weeks and it really works implausible. I’ve watched it put out 168 amps with no concern and only a couple tenths drop in voltage whereas doing it and then immediately returns to the traditional 13. 3 volts.
I have seen it charge in a short time at 68 amps from my photovoltaic array. The only difficulty I’ve had is that the BMS will put this battery on standby when my PV input matches the load on the battery… your entire system “pauses” causing the inverter to close off, the charge controller goes to relaxation, or to alarm and the 12-volt system goes lifeless for a couple of seconds… Be suggested the battery can go on standby…
View More KiloVault Helpful Reviews