Kilovault 1800 Chlx – KiloVault® is devoted to providing progressive and inexpensive renewable energy options for residential and commercial functions.
KiloVault® design, market, and sell power storage and energy conversion products based on modern applied sciences, that reduce the price of entry for householders, and assist cut back the influence of humanity on the setting.
Kilovault 1800 Chlx
KiloVault® has greater than 20 years of experience designing renewable power techniques. Our founders and lead improvement engineers have distinctive insight into the needs of the residential energy. This is simply their newest thought to help prospects store the sun, and save the planet.
Product Overview
Kilovault 1800 Chlx – KiloVault® Solar Energy Storage products cowl a wide range of applications, including Flexible Energy Storage, Wall-Mount Energy Storage, and Portable Emergency Power.
1. KiloVault HLX Series
KiloVault HLX-Series Deep- Cycle Lithium Batteries provide a configurable strategy to residential energy storage needs. The HLX Series can be utilized individually or in combination for 12, 24, or 48-volt techniques, with storage capacities starting from 150 Amp-hours to 1,200 Amp-hours.
KiloVault HLX Series Features:
- Flexible – Works in 12, 24, or 48V configurations
- Gives You More- You can use the complete battery’s capacity, discharging it 100%
- Long-life- Even after discharging it utterly 2000 times, 80% of the capacity stays.
- Maintenance Free – No watering required, or cleansing of hazardous chemical substances
- High Efficiency – Giving you as much as 12% more use-able saved power
- Smart Investment – Lower value per watt-hour/cycle and an extended lifespan than lead batteries
- Safer – No thermal run-away issues as with different lithium technologies
- Heavy Duty -Takes as much as 150A of continuous charging/discharging present, assembly the tough demands of serious inverters and chargers
- 7.5 Year Warranty
KiloVault HLX Series Product Specifications:
1200 HLX | 1800 HLX | 3600 HLX | |
---|---|---|---|
Battery Type | Li-FePO4 | Li-FePO4 | Li-FePO4 |
Rated Capacity | 1200Wh | 1800Wh | 3600Wh |
Rated Voltage | 12.8 V DC | 12.8 V DC | 12.8 V DC |
Nominal Amp-Hour Capacity | 100Ah | 150Ah | 300Ah |
Continuous Discharge Current | 100A | 150Ah | 150Ah |
Maximum Discharge Current | 100A | 150Ah | 200A for 30 min, 150A (continuous) |
Max Charge Current | 80A | 150Ah | 150Ah |
Peak Discharge Current < 3 secs | 350A | 500A | 500A |
Dimensions | |||
Length | 12.5 in (318 mm) | 19.1 in (485 mm) | 20.5 in (520 mm) |
Width | 6.5 in (165 mm) | 6.7 in (170 mm) | 8.7 in (220 mm) |
Height | 8.5 in (215 mm) | 9.4 in (240 mm) | 10.6 in (269 mm) |
Battery Weight | 27 lbs (12.2 kg) | 41.7 lbs (18.9kg) | 84.4 lbs (38.3 kg) |
Shipping Weight | 30 lbs (13.6 kg) | 45.2 lbs (20.5kg) | 103.4 lbs (46.9 kg) |
KiloVault 1800 HLX
2. KiloVault RES-Q
KiloVault RES-Q Portable Emergency Power Unit features a 1,200 Watt-Hour battery, charge controller, and inverter that can power a fridge and charge cell telephones. The KiloVault RES-Q is designed to be charged by solar panels, a backup generator, or commonplace 120 VAC energy, and can present as much as 1200Wh of emergency backup energy.
KiloVault RES-Q Features:
- 1500W Pure Sinewave Inverter
- 1200Wh KiloVault Lithium Battery
- 25A Solar Charge Controller
- Built-in AC Charger
- Liquid Crystal Display Status
- 2x 120V Outlets
- 1x 12V Cigarette Lighter Adapter
- Lead Acid Battery Expansion Port
KiloVault RES-Q Specifications:
1500 RES-Q | |
---|---|
Rated Energy Capacity (Watt Hours) | 1280 Wh |
DC Voltage Nominal | 12.8V |
Nominal Amp-Hour Capacity | 100 Ah |
Cycle Rating | 2500+ cycles @ 80% Depth of Discharge |
Minimum Charge Time | 2.5 Hours |
Charge Retention | 1 Year (85%) |
Integrated Inverter | 1500W steady output/120VAC pure sinewave/Slow start function protects inverter from over-current draw |
Maximum Charge Current | 15A @ 12V from AC or DC circuitry |
Maximum DC Output | 20A |
Operating Temperature | 23 – 111°F (-5 – 45°C) |
Surge Ratings | 3000W (5ms), Soft Start (for short surges) |
Environmental Rating | Indoor rated solely – not rated for wet, damp, snowy conditions |
Expansion Port for External Battery | We highly recommend utilizing an LFP battery (ie. KiloVault). The RES-Q completely discharges the exterior battery, right down to 10.5V, before switching to the internal battery. Completely discharging a lead-acid battery will possible harm it and completely scale back its capability. |
Warranty | 2 Year Limited |
Dimensions | |
Length | 18.9 in (480 mm) |
Width | 9.4 in (238 mm) |
Height | 15.7 in (400 mm) |
Weight | 61.7 lbs (28 kg) |
KiloVault RESQ 1500
KiloVault HLX Tips And FAQ
Is it good to insulate the KiloVault battery?
It’s the same with any sort of battery. Because batteries heat up once they charge, for those who insulate the field they are in, it’s going to retain the warmth better and the batteries will keep warmer. But make certain to remove the insulation within the scorching months, as overheated batteries can have a shorter life.
What is the very best working and storage temperature for the KiloVault?
The optimal temperature range general is 59 – 95°F (15 – 35°C). Full working temperatures must be greater than 32°F (O°C) and less than 133°F (45°C). Charging the battery under 32°F (0°C) will potentially harm it.
What are the really useful charge controller/inverter settings?
We highly recommend setting the Bulk/Absorb voltage to *14.0V* for a 12V system (*28.0V* for 24V system, *56.0V* for 48V), float voltage of 13.8V (27.6V for 24V, 55.2V for 48V). Higher settings will scale back the *life* of the batteries. For the inverter low voltage cut-off we strongly advocate 12.0V *or greater* (24.0V, for 24V techniques, 48.0V for 48V programs). Limit the duration of the take in voltage period to 2 minutes if the charger is greater than 100A, otherwise set to five minutes.
Are there any concerns when wiring the batteries in parallel?
Yes – for the HLX sequence batteries, the utmost configuration is 4 parallel strings of 4 sequence batteries (16). In addition, when adding one other parallel row of batteries to an existing one, it is important to preserve all parallel sequence strings within 0.2V of each other. Before adding a new row of batteries to an current one, charge all batteries to 100% first.
For the CHLX sequence batteries, a maximum of 4 batteries can be used in collection or parallel, but NOT both. The CHLX are programmed so that when they are in parallel or collection if one gets chilly enough to start heating, the entire CHLX in series or parallel will start heating. This is to prevent extensively totally different power attracts and states of charge in the battery financial institution when some are heating and can’t charge, while others are warm sufficient to charge. As the communication between the CHLX occurs via the ability cables, if related this fashion, this communication can not happen.
Can I combine and match models or brands?
No – this is not good observe with any battery financial institution.
Should I do an equalization charge on the batteries?
No- very like AGM batteries, an equalization charge may injury them by overcharging them.
Are the batteries shipped totally charged, or do I need to charge them?
No – transport pointers do not allow deep cycle batteries to be absolutely charged during shipment. **Before you place the batteries into operation they have to ALL be charged to precisely the identical voltage (select a voltage between 14.0-14.4, V but make certain they’re *ALL* the same). This will ensure you start with an even charge throughout the battery bank. Suggested battery charger (cables not included with this charger however are available – use item code ALTCC-6AWG-60RB). We do NOT counsel utilizing the Iota IQ-LIFE PO Smart Charger accent for use with KiloVault batteries because the charge voltage is just too high.
Can I do a continuing trickle charge on the batteries?
Storing the batteries with a relentless small trickle charge shouldn’t be really useful. Unlike lead-acid batteries, lithium iron phosphate batteries self-consume energy at such a low charge (0.020 amps or about 6 Watt-hours/day), the battery could be simply over-charged if placed on a trickle charger. Over-charging the battery triggers the over-charge protection – shutting it down until the voltage goes down sufficient by itself. Once that occurs the trickle charger would quickly elevate the voltage up too excessive as soon as once more. As a end result, the constant cycling of this circuitry will shorten the life of the whole battery.
Is it bad to overcharge or over-discharge the battery?
Yes, this may decrease the life of the battery. It’s recommended to never discharge or charge the battery to the point the place it has to close down to guard itself.
View Complete KiloVault Product And Discount Price
Customer Reviews
Kilovault 1800 Chlx – I have been working my new system with the KiloVault 3600 HLX for two weeks and it really works implausible. I’ve watched it put out 168 amps with no challenge and solely a couple tenths drop in voltage whereas doing it after which immediately returns to the normal 13. 3 volts.
I’ve seen it charge in a short time at 68 amps from my photovoltaic array. The only concern I have had is that the BMS will put this battery on standby when my PV input matches the load on the battery… the entire system “pauses” causing the inverter to shut off, the charge controller goes to relaxation, or to alarm and the 12-volt system goes dead for a couple of seconds… Be advised the battery can go on standby…
View More KiloVault Helpful Reviews