AIMS Power AC Converter Battery Charger 12V & 24V Smart Charger 75 Amps – Listed to UL 458/CSA | CON120AC1224VDC + FREE Shipping, NO Sales Tax & Lifetime Customer Support FREE Shipping, NO Sales Tax & Lifetime Customer Support Boasting versatility and a high charging capacity, the AIMS 12V…
AIMS Power AC Converter Battery Charger 12V& 24V Smart Charger 75 Amps – Listed to UL 458/CSA | CON120AC1224VDC + FREE Shipping, NO Sales Tax& Lifetime Customer Support
FREE Shipping, NO Sales Tax& Lifetime Customer Support
Boasting versatility and a high charging capacity, the AIMS 12V and 24V AC 75-Amp Converter/Battery Charger from AIMS Power provides wide latitude to meet the demands of many applications. This unit’s broad AC input range of 70VAC to 145VAC can handle many applications and battery technologies. It automatically detects 12VDC and 24VDC battery banks. Useful with generators and shore power, it can charge batteries including open lead-acid, AGM, gel, and LiFeP04.
This unit’s 75-amp charging capacity gets the job done in a hurry. It can charge a 100 amp-hour battery up to a 90 percent charge in less than an hour. That makes it ideal for RVs, boats, campers, and many other applications.
Reverse-polarity, over-voltage, and under-voltage protections provide peace of mind along with short-circuiting and over-temperature safeguards. Listed to UL 458 and CSA 22.2, this unit comes with a two-year manufacturer’s warranty.
AIMS Power AC Converter Features:
- Large charging capacity design (75 Amp for 12Vdc37.5 Amp for 24Vdc) charges a 100 amp hour battery in under an hour up to 90% charge
- Power supply up to 75 amps at 12Vdc or 37.5 amps at 24Vdc
- Three-stage smart charger with variable charging voltage algorithm for maximizing battery life (bulk, absorb, and float)
- 4 pre-programmed charging algorithms using the dip switches for the most common charging profiles
- Charges lead-acid, AGM, GEL, and LiFPO4 batteries
- Adjustable charge current control dial to safely charge the smaller battery (s)
- Wide input voltage range, 70Vac to 145Vac for unstable inputs
- Reverse polarity, over-voltage, under-voltage, short circuit, over-temperature protection
- High AC to DC converting efficiency design >80%
- Smart fan control for maximizing the performance and fan life
- Includes battery temperature sensor port to help maintain the life of the battery(s) (battery temperature sensor not included)
- AC input cord 4ft
- Listed to UL 458 and CSA 22.2 NO. 107.1
- 2-year warranty
AIMS Power AC Converter Specifications:
Input Voltage | 96-145VAC full performance |
70-96VAC automatically de-rate to 50% of full load current | |
Frequency | 40Hz to 70Hz |
Nominal Input Current at Rated Output | >9Aac |
Voltage Measurement Accuracy | ±8Vac |
Frequency Measurement Accuracy | ±1Hz |
Output | |
---|---|
Nominal Voltage | 12/24Vdc manual adjustable |
Output Current | Input voltage 96-145V, output current 75A for 12V mode output current 37.5A for 24V mode |
Input voltage 70-96V, output current 37.5A for 12V mode output current 18.75A for 24V mode | |
Rated Output Current | Manual adjustable |
Current Accuracy | ± 6% of full rated output current @25°C, for target currents across the range from 10% rated output (for absorption exit criteria accuracy) to the current limit set point. |
Load Regulation | 1.5% |
Current Limit | 75-80Amp |
Dead-Battery Charging | 8-14.9Vdc at 100% of rated output current |
8-29.8Vdc at 100% of rated output current | |
Selectable Battery Type | Open Lead-Acid, Gel, AGM, LiFePo4, adjustable |
Parallel Outputs | Maximum of two AC converter units connected in parallel |
Efficiency | 80% |
Protection | |
Input Over Voltage | The unit must be safe for input voltage up to 150VacRMS (and up to 215Vpeak), need not be operating. Above this level, the unit may be damaged. |
Reverse Battery Polarity Protection | Non-destructive reverse battery polarity protection with fuses. Unit shall not sustain damage and shall meet all specifications after fuse replacement. |
Input Under-voltage | The unit must not be damaged for all input voltages from 0-300Vac. Shutdown or input current limit or other means may be applied when the input voltage is out of the normal operating range. |
Output over voltage 12/24V mode | 12Vdc. The unit will shut down if Vcharging>Vcharging (target) + 1.0Vdc for more than 2 seconds the unit will restart when voltage<= Vcharging (target) for more than 2 seconds. For battery OVP the unit will restart in the same stage. |
24Vdc. The unit will shut down if Vcharging>Vcharging (target) + 1.5Vdc for more than 2 seconds the unit will restart when voltage<= Vcharging (target) for more than 2 seconds. For battery OVP the unit will restart in the same stage. | |
Charger over-temperature protection | The internal temperatures of the charger will be measured by NTC. Based on these measurements, the unit will shut down if the temperature exceeds 105°C. The unit will restart when the environment temperature cools to 95 °C. |
BTS(Battery Temperature Sensing) | The battery temperature sensor allows the charge controller to continuously adjust the charge voltage/charge current based on the actual battery temperature. When the battery temperature is over 40 °C, the unit will reduce the charging voltage to Float voltage, also it will reduce the Max charging current by 10% with every two degrees of temperature rise. When the battery temperature is over 50 °C, the unit will shut down. |
Environmental | |
Operation temperature | Nominal ambient temperature: 25°C Operating Ambient Temperature range: -10°C to 40°C (On the heat sink of the DC-DC part, if the temperature is over 90 ?, the Charger Current will be de-rate to 50%if the temperature is over 105 ?, the Unit will be shut down.) |
Relative humidity | 5 – 95% without condensation |
Noise | Unit requirements: below 50dB (A) measured at 1 m distance with fan fully working. |
Storage Conditions Temperature | -20°C to +80°C |
Cooling | Smart fan control |
Safety | UL458?CSA22.2#107.1 |
Mechanical | |
Dimension (D x W x H) mm | 10.25″ * 6.75″ * 3.25″ |
Unit Weight | 6.5 lb |
Boxed Weight | 7 lb |