Kilovault 2100 Plc – KiloVault® is devoted to providing modern and affordable renewable energy options for residential and commercial functions.
KiloVault® design, market, and sell energy storage and power conversion products primarily based on modern applied sciences, that cut back the cost of entry for homeowners, and assist reduce the impact of humanity on the atmosphere.
Kilovault 2100 Plc
KiloVault® has more than 20 years of expertise designing renewable vitality techniques. Our founders and lead development engineers have unique perception into the wants of the residential power. This is simply their latest concept to assist customers store the solar, and save the planet.
Product Overview
Kilovault 2100 Plc – KiloVault® Solar Energy Storage merchandise cover a wide range of applications, including Flexible Energy Storage, Wall-Mount Energy Storage, and Portable Emergency Power.
1. KiloVault HLX Series
KiloVault HLX-Series Deep- Cycle Lithium Batteries provide a configurable approach to residential vitality storage wants. The HLX Series can be used individually or together for 12, 24, or 48-volt systems, with storage capacities starting from 150 Amp-hours to 1,200 Amp-hours.
KiloVault HLX Series Features:
- Flexible – Works in 12, 24, or 48V configurations
- Gives You More- You can use the total battery’s capability, discharging it 100%
- Long-life- Even after discharging it utterly 2000 instances, 80% of the capacity remains.
- Maintenance Free – No watering required, or cleaning of hazardous chemicals
- High Efficiency – Giving you as much as 12% more use-able saved vitality
- Smart Investment – Lower price per watt-hour/cycle and a longer lifespan than lead batteries
- Safer – No thermal run-away points as with different lithium technologies
- Heavy Duty -Takes up to 150A of continuous charging/discharging current, meeting the powerful demands of serious inverters and chargers
- 7.5 Year Warranty
KiloVault HLX Series Product Specifications:
1200 HLX | 1800 HLX | 3600 HLX | |
---|---|---|---|
Battery Type | Li-FePO4 | Li-FePO4 | Li-FePO4 |
Rated Capacity | 1200Wh | 1800Wh | 3600Wh |
Rated Voltage | 12.8 V DC | 12.8 V DC | 12.8 V DC |
Nominal Amp-Hour Capacity | 100Ah | 150Ah | 300Ah |
Continuous Discharge Current | 100A | 150Ah | 150Ah |
Maximum Discharge Current | 100A | 150Ah | 200A for 30 min, 150A (steady) |
Max Charge Current | 80A | 150Ah | 150Ah |
Peak Discharge Current < 3 secs | 350A | 500A | 500A |
Dimensions | |||
Length | 12.5 in (318 mm) | 19.1 in (485 mm) | 20.5 in (520 mm) |
Width | 6.5 in (165 mm) | 6.7 in (170 mm) | 8.7 in (220 mm) |
Height | 8.5 in (215 mm) | 9.4 in (240 mm) | 10.6 in (269 mm) |
Battery Weight | 27 lbs (12.2 kg) | 41.7 lbs (18.9kg) | 84.4 lbs (38.3 kg) |
Shipping Weight | 30 lbs (13.6 kg) | 45.2 lbs (20.5kg) | 103.4 lbs (46.9 kg) |
KiloVault 1800 HLX
2. KiloVault RES-Q
KiloVault RES-Q Portable Emergency Power Unit includes a 1,200 Watt-Hour battery, charge controller, and inverter that may power a fridge and charge cell phones. The KiloVault RES-Q is designed to be charged by photovoltaic panels, a backup generator, or normal 120 VAC power, and will present as much as 1200Wh of emergency backup energy.
KiloVault RES-Q Features:
- 1500W Pure Sinewave Inverter
- 1200Wh KiloVault Lithium Battery
- 25A Solar Charge Controller
- Built-in AC Charger
- Liquid Crystal Display Status
- 2x 120V Outlets
- 1x 12V Cigarette Lighter Adapter
- Lead Acid Battery Expansion Port
KiloVault RES-Q Specifications:
1500 RES-Q | |
---|---|
Rated Energy Capacity (Watt Hours) | 1280 Wh |
DC Voltage Nominal | 12.8V |
Nominal Amp-Hour Capacity | 100 Ah |
Cycle Rating | 2500+ cycles @ 80% Depth of Discharge |
Minimum Charge Time | 2.5 Hours |
Charge Retention | 1 Year (85%) |
Integrated Inverter | 1500W steady output/120VAC pure sinewave/Slow start feature protects inverter from over-current draw |
Maximum Charge Current | 15A @ 12V from AC or DC circuitry |
Maximum DC Output | 20A |
Operating Temperature | 23 – 111°F (-5 – 45°C) |
Surge Ratings | 3000W (5ms), Soft Start (for short surges) |
Environmental Rating | Indoor rated solely – not rated for rainy, damp, snowy situations |
Expansion Port for External Battery | We highly suggest using an LFP battery (ie. KiloVault). The RES-Q utterly discharges the exterior battery, all the way down to 10.5V, before switching to the interior battery. Completely discharging a lead-acid battery will seemingly injury it and permanently cut back its capability. |
Warranty | 2 Year Limited |
Dimensions | |
Length | 18.9 in (480 mm) |
Width | 9.4 in (238 mm) |
Height | 15.7 in (400 mm) |
Weight | 61.7 lbs (28 kg) |
KiloVault RESQ 1500
KiloVault HLX Tips And FAQ
Is it good to insulate the KiloVault battery?
It’s the same with any type of battery. Because batteries heat up after they charge, in the event you insulate the box they are in, it would retain the heat higher and the batteries will stay hotter. But make sure that to remove the insulation within the hot months, as overheated batteries could have a shorter life.
What is the very best operating and storage temperature for the KiloVault?
The optimal temperature vary overall is 59 – 95°F (15 – 35°C). Full working temperatures should be greater than 32°F (O°C) and less than 133°F (45°C). Charging the battery under 32°F (0°C) will probably damage it.
What are the advisable charge controller/inverter settings?
We highly recommend setting the Bulk/Absorb voltage to *14.0V* for a 12V system (*28.0V* for 24V system, *56.0V* for 48V), float voltage of 13.8V (27.6V for 24V, 55.2V for 48V). Higher settings will cut back the *life* of the batteries. For the inverter low voltage cut-off we strongly recommend 12.0V *or increased* (24.0V, for 24V methods, 48.0V for 48V methods). Limit the length of the take in voltage period to 2 minutes if the charger is greater than 100A, otherwise set to five minutes.
Are there any considerations when wiring the batteries in parallel?
Yes – for the HLX collection batteries, the maximum configuration is 4 parallel strings of 4 collection batteries (16). In addition, when adding another parallel row of batteries to an present one, it is very important preserve all parallel series strings within 0.2V of one another. Before adding a new row of batteries to an present one, charge all batteries to 100% first.
For the CHLX sequence batteries, a maximum of 4 batteries can be utilized in collection or parallel, however NOT each. The CHLX are programmed in order that when they are in parallel or sequence if one will get chilly enough to start heating, the entire CHLX in series or parallel will begin heating. This is to forestall widely completely different power attracts and states of charge within the battery bank when some are heating and can’t charge, whereas others are heat sufficient to charge. As the communication between the CHLX occurs by way of the power cables, if related this way, this communication can not take place.
Can I combine and match models or brands?
No – this isn’t good apply with any battery bank.
Should I do an equalization charge on the batteries?
No- much like AGM batteries, an equalization charge may damage them by overcharging them.
Are the batteries shipped fully charged, or do I need to charge them?
No – transport guidelines do not enable deep cycle batteries to be absolutely charged throughout shipment. **Before you place the batteries into operation they have to ALL be charged to exactly the identical voltage (choose a voltage between 14.0-14.4, V but be certain that they’re *ALL* the same). This will ensure you start with an excellent charge across the battery bank. Suggested battery charger (cables not included with this charger however can be found – use merchandise code ALTCC-6AWG-60RB). We do NOT counsel using the Iota IQ-LIFE PO Smart Charger accessory to be used with KiloVault batteries because the charge voltage is just too excessive.
Can I do a continuing trickle charge on the batteries?
Storing the batteries with a constant small trickle charge is not beneficial. Unlike lead-acid batteries, lithium iron phosphate batteries self-consume power at such a low rate (0.020 amps or about 6 Watt-hours/day), the battery might be easily over-charged if placed on a trickle charger. Over-charging the battery triggers the over-charge protection – shutting it down till the voltage goes down enough by itself. Once that happens the trickle charger would quickly raise the voltage up too high as soon as again. As a outcome, the fixed cycling of this circuitry will shorten the life of all the battery.
Is it unhealthy to overcharge or over-discharge the battery?
Yes, this will lower the lifetime of the battery. It’s advisable to by no means discharge or charge the battery to the point the place it has to shut down to protect itself.
View Complete KiloVault Product And Discount Price
Customer Reviews
Kilovault 2100 Plc – I’ve been running my new system with the KiloVault 3600 HLX for two weeks and it really works unbelievable. I’ve watched it put out 168 amps with no issue and solely a couple tenths drop in voltage while doing it and then instantly returns to the normal 13. 3 volts.
I have seen it charge very quickly at 68 amps from my solar array. The solely concern I’ve had is that the BMS will put this battery on standby when my PV enter matches the load on the battery… all the system “pauses” causing the inverter to close off, the charge controller goes to relaxation, or to alarm and the 12-volt system goes dead for a couple of seconds… Be suggested the battery can go on standby…
View More KiloVault Helpful Reviews